DOI 10.1186/s12912-026-04780-z
Occupational radiation exposure and crystalline lens density in perioperative nurses: a short communication.
Аннотация
BACKGROUND
The rising use of C-arm fluoroscopy in operating rooms raises occupational safety concerns for perioperative nurses. They may face scattered ionizing radiation despite not being classified as radiation workers. This study compared posterior Crystalline Lens Density a key indicator of radiation-induced cataract among perioperative nurses working with C-arm fluoroscopy, interventional radiology staff, and a non-exposed control group to determine whether intermittent occupational exposure is associated with measurable lens changes.
METHODS
In this Cross-sectional comparative study, 150 participants (50 perioperative nurses with C-arm exposure, 50 non-exposed or staff, and 50 interventional radiology personnel) underwent standardized ophthalmic examination. Pentacam Nucleus Staging quantified posterior lens density; the worse eye was analyzed. Groups were compared using chi-square tests and ANCOVA with Bonferroni correction.
RESULTS
Interventional radiology personnel exhibited significantly higher crystalline lens density (8.99 ± 1.50) compared with both perioperative nurses (8.40 ± 0.69; mean difference: 0.53, p = 0.001) and the control group (8.20 ± 0.27; mean difference: 0.70, p < 0.001). No significant difference was observed between perioperative nurses and controls (mean difference: 0.17, p = 0.539). The frequency of posterior subcapsular opacities (6.1% vs. 3.0% vs. 2.0%, p = 0.001), PNS grade ≥ 1 (17.1% vs. 8.0% vs. 3.9%, p = 0.002), and overall cataract prevalence (19.5% vs. 6.0% vs. 4.0%, p = 0.001) were all significantly higher in the interventional radiology group, with no significant differences between perioperative nurses and controls.
CONCLUSION
Perioperative nurses showed no significant difference compared with unexposed controls. These findings suggest that intermittent C-arm exposure under typical distancing conditions poses minimal measurable risk. Specifically, such exposure does not appear to increase radiation-related lens changes.
TRIAL REGISTRATION: Clinical trial number not applicable.