m+Medelevator.RU
← Поиск публикаций
PloS one · 2026

Comparison of general anesthesia versus no anesthesia in elective transjugular intrahepatic portosystemic shunt (TIPS): Procedural and hemodynamic parameters.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Maksoud Ziad, Köhler Michael, Nacul Mora Gala, Möllmann Florian, Masthoff Max, Eßeling Rainer, Strauß Patrick, Meier Arne, Kimmann Markus, Trebicka Jonel, Praktiknjo Michael, Pöhler Gesa Helen

Аннотация

Transjugular intrahepatic portosystemic shunt (TIPS) is an established treatment for complications of portal hypertension; yet the influence of anesthesia modality on procedural performance and hemodynamics remains insufficiently characterized. This retrospective single-center study compared radiation exposure, procedural parameters, and portal hemodynamics between procedures performed with and without general anesthesia (GA). A total of 84 patients were identified, of whom 62 were age- and sex-matched into two equal groups: group 1 (GA, n = 31) and group 2 (no GA, n = 31). Evaluated parameters included length of hospital stay, dose area product (DAP), fluoroscopy time (FT), contrast volume, number of digital subtraction angiography series, procedure duration, and pre- and post-TIPS measurements of portal venous pressure, central venous pressure (CVP), and portosystemic pressure gradient (PPG). Non-parametric statistical tests were applied. Patients in group 1 had significantly shorter postoperative hospital stay (median 6 days; interquartile range (IQR): 4-7) than those in group 2 (8 days; IQR 6-8; p = 0.006). Radiation dose was significantly lower in group 1, with a median DAP of 127.1 Gy*cm2 (IQR 64.6-201.8) compared to 325 Gy*cm2 (IQR 162.3-393.7; p = 0.02) in group 2. FT was also reduced under GA (12.2 minutes; IQR 9.6-15.9 vs. 16.0 minutes; IQR 11.5-25.9; p = 0.01), as was contrast volume (75 ml; IQR 60-100 vs. 90 mL; IQR 60-110; p = 0.01). PPG reduction was achieved in both groups, despite higher CVP under GA. These findings suggest that GA may facilitate more stable procedural conditions during TIPS, reducing radiation dose and contrast use without compromising hemodynamic effectiveness.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты