MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0289135

Медицинская библиотека · PloS one · 2023

Characteristics of ciliary muscle profile in high myopes measured by swept-source anterior segment optical coherence tomography.

Kwok Hiu Yin, Kwok Hoi Yee, Ng Tsz Nok, Leung Tsz-Wing, Kang Byung Soo, Kee Chea-Su

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To characterize and compare the ciliary muscle thickness (CMT) between low and high myopes using swept-source anterior segment optical coherence tomography (AS-OCT).

METHODS

Forty visually healthy young Chinese adults aged 18-25 years were divided into two groups based on refractive errors: low myopia (n = 20, spherical-equivalent refractive error (SER) between -0.50 D to -3.00 D) and high myopia (n = 20, SER ≤ -6.00 D). Cycloplegic refractions were performed before axial length (AL) and CMT were measured using a partial coherence laser interferometer and an AS-OCT respectively. CMT was measured perpendicularly to the sclera-ciliary muscle interface at 1 mm (CMT_1), 2 mm (CMT_2), and 3 mm (CMT_3) posterior to the scleral spur, and at the location with maximal thickness (CMT_MAX).

RESULTS

High myopes demonstrated thicker CMT at 2 mm (CMT_2, p = 0.035) and 3 mm (CMT_3, p = 0.003) posterior to the scleral spur, but thinner maximal CMT (CMT_MAX, p = 0.005) than low myopes. The apical CMT_1 and CMT_MAX were also thinner in high myopes than in low myopes (both p< 0.001). CMT_MAX, apical CMT_1, and apical CMT_MAX correlated directly with SER and inversely with AL; in contrast, CMT_2 and CMT_3 showed inverse correlations with SER but direct correlations with AL.

CONCLUSION

Our findings revealed significant differences in CMT between low and high myopes, with high myopes showing thicker CMT at 2 mm and 3 mm posterior to the scleral spur, but thinner maximal CMT. These results provide new evidence of the potential structural differences in ciliary muscles during myopia development and progression.

Для цитирования: Kwok Hiu Yin, Kwok Hoi Yee, Ng Tsz Nok, Leung Tsz-Wing, Kang Byung Soo, Kee Chea-Su. Characteristics of ciliary muscle profile in high myopes measured by swept-source anterior segment optical coherence tomography.. PloS one. 2023. DOI: 10.1371/journal.pone.0289135.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.