MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001304

Медицинская библиотека · Journal of cataract and refractive surgery · 2024

Comparative evaluation of multiple nomograms for predicting postoperative vault after implantable collamer lens surgery.

Moshirfar Majid, Han Kenneth D, Jaafar Muhammed A, Santos Jordan M, Theis Joshua S, Stoakes Isabella M, Hoopes Philip C

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the vault predictability of most available implantable collamer lens (ICL) sizing nomograms and identify which preoperative measurements are predictive of vault.

SETTING

Private practice in Draper, Utah.

DESIGN

Retrospective chart review.

METHODS

This study was a retrospective analysis of 209 eyes of 106 patients who underwent STAAR Surgical ICL implantation. Analyses were performed based on the availability of preoperative parameters, varying the number of eyes for each test. Mean absolute error (MAE) of predicted vs actual postoperative vault was calculated for each nomogram. The frequency of Kim, Rocamora (least absolute shrinkage and selection operator-optical coherence tomography), Russo, and Reinstein recommending the correct ICL size in instances when Parkhurst, optimized white-to-white (WTW), and STAAR could not recommend a definitive ICL size was determined. Univariate and multivariate linear regression analysis was performed between preoperative measurements and vault.

RESULTS

The Kim, Rocamora, Russo, and Reinstein nomograms had significantly lower MAE of predicted vs actual postoperative vault than the KSV2 and Nakamura V3 nomograms. The Russo formula most frequently recommended the correct ICL size when the Parkhurst, Optimized WTW, and STAAR nomograms could not provide ICL size recommendations. At the 0.05 significance level, anterior chamber depth (ACD), ciliary body inner diameter (CBID), and pupil diameter were the parameters found to have significant correlation with postoperative vault.

CONCLUSIONS

The Kim, Rocamora, Russo, and Reinstein nomograms were the most predictive of vault. Additionally, ACD, CBID, and pupil diameter were found to be significantly correlated with vault and should be considered for use in future ICL sizing nomograms.

Для цитирования: Moshirfar Majid, Han Kenneth D, Jaafar Muhammed A, Santos Jordan M, Theis Joshua S, Stoakes Isabella M, Hoopes Philip C. Comparative evaluation of multiple nomograms for predicting postoperative vault after implantable collamer lens surgery.. Journal of cataract and refractive surgery. 2024. DOI: 10.1097/j.jcrs.0000000000001304.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.