Evaluation of ciliary body morphology and position of the implantable collamer lens in low-vault eyes using ultrasound biomicroscopy.

Yiming Ye, Xi Chen, Huan Yao, Liming Chen, Na Yu, Pei Chen, Ying Yang, Yan Li, Keming Yu

Наблюдательное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the ciliary body anatomy and position of the implantable collamer lens (ICL) in low-vault eyes and analyze factors related to insufficient vault.

SETTING

Zhongshan Ophthalmic Center, Guangzhou, China.

DESIGN

Retrospective case-control observational study.

METHODS

In this study, 73 eyes of 73 patients with an insufficient vault (<250 μm) were matched with 73 eyes with an ideal vault (250 to 750 μm). Ultrasound biomicroscopy was used to determine the ciliary body morphology and ICL position. The biometric parameters acquired by Scheimpflug tomography were compared. The correlation between the vault and these factors was analyzed, and the least absolute shrinkage and selection operator method was used to screen the risk factors for low vault.

RESULTS

The low-vault group had a steeper corneal curvature, thicker lens thickness (LT), higher crystalline lens rise, and shorter axial length (AL) (all P < .005). The ciliary process length (CPL) and maximum ciliary body thickness (CBTmax) were significantly smaller, and the trabecular-ciliary angle (TCA), iris-ciliary angle (ICA), and ciliary sulcus width (CSW) were significantly greater in the low-vault eyes (all P < .005). The low-vault group had more ICL haptics below the ciliary process, and TCA, ICA, CPL, CBTmax, CSW, and haptic position were related to the postoperative vault (all P < .05). CPL, AL, and LT were identified as predictors of a low vault.

CONCLUSIONS

Malposition of ICL haptics behind the ciliary process is a risk factor for low vault. A shorter CPL, thicker LT, and shorter AL are significant risk factors for the postoperative low vault.

Для цитирования: Yiming Ye, Xi Chen, Huan Yao, Liming Chen, Na Yu, Pei Chen, Ying Yang, Yan Li, Keming Yu. Evaluation of ciliary body morphology and position of the implantable collamer lens in low-vault eyes using ultrasound biomicroscopy.. Journal of cataract and refractive surgery. 2023. DOI: 10.1097/j.jcrs.0000000000001285.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.