Heart rhythm · 2018
Feasibility of complex transfemoral electrophysiology procedures in patients with inferior vena cava filters.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mendelson Todd B, Santangeli Pasquale, Frankel David S, Arkles Jeffrey S, Supple Gregory E, Lin David, Riley Michael P, Callans David J, Nazarian Saman, Hyman Matthew C, Kumareswaran Ramanan, Epstein Andrew E, Deo Rajat, Dixit Sanjay, Garcia Fermin C, Zado Erica S, Hutchinson Mathew D, Sadek Mouhannad M, Cooper Joshua M, Marchlinski Francis E, Trerotola Scott O, Schaller Robert D
Аннотация
BACKGROUND: The presence of inferior vena cava filters (IVCFs) has been considered a relative contraindication to electrophysiology (EP) procedures that require transfemoral venous placement of multiple catheters and/or long sheaths. There are inadequate data related to complex EP procedures in this population.
OBJECTIVE: The purpose of this study was to describe the experience of a single high-volume center with respect to complex EP procedures in patients with IVCFs.
METHODS: Patients with IVCFs undergoing complex EP procedures between 2004 and 2018 were identified. Clinical characteristics, IVCF type, procedural findings, and complications were analyzed.
RESULTS: Fifty complex ablation procedures were performed in 40 patients (mean age 63.8 ± 10.9 years; 68% men). The mean IVCF dwell time was 69.1 ± 19.1 months, and 48 patients (96%) were on chronic oral anticoagulation. Procedures included ablation of atrial fibrillation (n = 21), ventricular tachycardia (n = 20), supraventricular tachycardia (n = 3), cavotricuspid isthmus flutter (n = 3), supraventricular tachycardia and cavotricuspid isthmus flutter (n = 1), and transvenous lead extraction (n = 3). Twenty procedures included quadripolar catheters (mean 1.4 ± 0.75), and 33 procedures involved deflectable decapolar catheters (mean 1.7 ± 0.47). Long sheaths were used in 35 cases (mean 1.63 ± 0.49) and intracardiac echocardiography in 38. In 4 cases (involving 3 patients), the IVCF was occluded and could not be crossed. There were no procedural complications related to the IVCF.
CONCLUSION: The substantial majority of IVCFs in patients presenting for complex EP procedures were patent and easily crossed under fluoroscopic guidance. The presence of an IVCF should not discourage operators from performing procedures that require transfemoral deployment of multiple catheters and/or sheaths.
OBJECTIVE: The purpose of this study was to describe the experience of a single high-volume center with respect to complex EP procedures in patients with IVCFs.
METHODS: Patients with IVCFs undergoing complex EP procedures between 2004 and 2018 were identified. Clinical characteristics, IVCF type, procedural findings, and complications were analyzed.
RESULTS: Fifty complex ablation procedures were performed in 40 patients (mean age 63.8 ± 10.9 years; 68% men). The mean IVCF dwell time was 69.1 ± 19.1 months, and 48 patients (96%) were on chronic oral anticoagulation. Procedures included ablation of atrial fibrillation (n = 21), ventricular tachycardia (n = 20), supraventricular tachycardia (n = 3), cavotricuspid isthmus flutter (n = 3), supraventricular tachycardia and cavotricuspid isthmus flutter (n = 1), and transvenous lead extraction (n = 3). Twenty procedures included quadripolar catheters (mean 1.4 ± 0.75), and 33 procedures involved deflectable decapolar catheters (mean 1.7 ± 0.47). Long sheaths were used in 35 cases (mean 1.63 ± 0.49) and intracardiac echocardiography in 38. In 4 cases (involving 3 patients), the IVCF was occluded and could not be crossed. There were no procedural complications related to the IVCF.
CONCLUSION: The substantial majority of IVCFs in patients presenting for complex EP procedures were patent and easily crossed under fluoroscopic guidance. The presence of an IVCF should not discourage operators from performing procedures that require transfemoral deployment of multiple catheters and/or sheaths.
Предметные рубрики MeSH
AnticoagulantsArrhythmias, CardiacCardiac CatheterizationCatheter AblationCatheterization, PeripheralCathetersDevice RemovalElectrophysiologic Techniques, CardiacFeasibility StudiesFemaleFemoral VeinHumansMaleMiddle AgedOutcome and Process Assessment, Health CareSurgery, Computer-AssistedVena Cava FiltersVenous Thrombosis