Double trouble: A case of periprocedural detection of intracardiac thrombus and aortic root dissection during emergent transfemoral TAVR.

Corredor Carlos, Horlick Eric, Tsang Wendy, Meineri Massimiliano

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

We report a case of emergency transcatheter aortic valve replacement (TAVR) in a 65-year-old patient presenting with decompensated severe aortic stenosis. Transesophageal echocardiography (TEE) was used effectively to obtain measurements of the aortic annulus and for intra-procedural guidance. At baseline, we detected a left atrial appendage thrombus and a localized aortic root dissection after balloon valvuloplasty. The case highlights the important role that TEE may play during TAVR procedures.

Для цитирования: Corredor Carlos, Horlick Eric, Tsang Wendy, Meineri Massimiliano. Double trouble: A case of periprocedural detection of intracardiac thrombus and aortic root dissection during emergent transfemoral TAVR.. Echocardiography (Mount Kisco, N.Y.). 2017. DOI: 10.1111/echo.13437.