MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mrm.28587

Медицинская библиотека · Magnetic resonance in medicine · 2020

Repeatability and reliability of GABA measurements with magnetic resonance spectroscopy in healthy young adults.

Duda Jessica M, Moser Amelia D, Zuo Chun S, Du Fei, Chen Xi, Perlo Sarah, Richards Christine E, Nascimento Nara, Ironside Maria, Crowley David J, Holsen Laura M, Misra Madhusmita, Hudson James I, Goldstein Jill M, Pizzagalli Diego A

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: Gamma-aminobutyric acid (GABA) abnormalities have been implicated in a range of neuropsychiatric disorders. Despite substantial interest in probing GABA in vivo, human imaging studies relying on magnetic resonance spectroscopy (MRS) have generally been hindered by technical challenges, including GABA's relatively low concentration and spectral overlap with other metabolites. Although past studies have shown moderate-to-strong test-retest repeatability and reliability of GABA within certain brain regions, many of these studies have been limited by small sample sizes.

METHODS

GABA+ (macromolecular-contaminated) test-retest reliability and repeatability were assessed via a Meshcher-Garwood point resolved spectroscopy (MEGA-PRESS) MRS sequence in the rostral anterior cingulate cortex (rACC; n = 21) and dorsolateral prefrontal cortex (dlPFC; n = 20) in healthy young adults. Data were collected on a 3T scanner (Siemens Prisma, Siemens Healthcare, Erlangen, Germany) and GABA+ results were reported in reference to both total creatine (GABA+/tCr) and water (GABA+/water).

RESULTS

Results showed strong test-retest repeatability (mean GABA+/tCr coefficient of variation [CV] = 4.6%; mean GABA+/water CV = 4.0%) and reliability (GABA+/tCr intraclass correlation coefficient [ICC] = 0.77; GABA+/water ICC = 0.87) in the dlPFC. The rACC showed acceptable (but comparatively lower) repeatability (mean GABA+/tCr CV = 8.0%; mean GABA+/water CV = 7.5%), yet low-moderate reliability (GABA+/tCr ICC = 0.40; GABA+/water ICC = 0.44).

CONCLUSION

The present study found excellent GABA+ MRS repeatability and reliability in the dlPFC. The rACC showed inferior results, possibly because of a combination of shimming impedance and measurement error. These data suggest that MEGA-PRESS can be utilized to reliably distinguish participants based on dlPFC GABA+ levels, whereas the mixed results in the rACC merit further investigation.

Для цитирования: Duda Jessica M, Moser Amelia D, Zuo Chun S, Du Fei, Chen Xi, Perlo Sarah, Richards Christine E, Nascimento Nara, Ironside Maria, Crowley David J, Holsen Laura M, Misra Madhusmita, Hudson James I, Goldstein Jill M, Pizzagalli Diego A. Repeatability and reliability of GABA measurements with magnetic resonance spectroscopy in healthy young adults.. Magnetic resonance in medicine. 2020. DOI: 10.1002/mrm.28587.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.