m+Medelevator.RU
← Поиск публикаций
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2022

Comprehensive analysis of haemodynamics in patients with physiologically curved prostheses of the ascending aorta.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sieren Malte Maria, Balks Maren Friederike, Schlueter Jennifer Kristina, Wegner Franz, Huellebrand Markus, Scharfschwerdt Michael, Barkhausen Jörg, Frydrychowicz Alex, Gabbert Dominik Daniel, Oechtering Thekla Helene

Аннотация

OBJECTIVES: This is a comprehensive analysis of haemodynamics after valve-sparing aortic root replacement (VSARR) with anatomically curved prosthesis (CP) compared to straight prosthesis (SP) and age-matched volunteers (VOL) using 4D flow MRI (time-resolved three-dimensional magnetic resonance phase-contrast imaging).

METHODS: Nine patients with 90° CP, nine patients with SP, and twelve VOL were examined with 4D flow MRI. Analyses included various characteristic anatomical, qualitative and quantitative haemodynamic parameters.

RESULTS: Grading of secondary flow patterns was lower in CP patients than in SP patients (P = 0.09) and more comparable to VOL, albeit not reaching statistical significance. However, it was easy to differentiate between VSARR patients and healthy volunteers: Patients more often had angular aortic arches (CP: 89%, SP: 100%; VOL: 17%; P ≤ 0.002), increased average curvature (CP: 0.17/cm [0.15, 0.18]; SP: 0.15/cm [0.14, 0.16]; VOL: 0.14/cm [0.13, 0.16]; P ≤ 0.007; values given as median [interquartile range]), and more secondary flow patterns (CP: 3 [2, 4] SP: 3 [2, 3] VOL: 2 [1, 2]; P < 0.01). Maximum circulation (CP: 142.7 cm2/s [116.1, 187.3]; SP: 101.8 cm2/s [77.7, 132.5]; VOL: 42.8cm2/s [39.3, 65.6]; P ≤ 0.002), maximum helicity density (CP: 9.6 m/s2 [9.3, 23.9]; SP: 9.7 m/s2 [8.6, 12.5]; VOL 4.9 m/s2 [4.2, 7.7]; P ≤ 0.007), and wall shear stress gradient (e.g., proximal ascending aorta CP: 0.97 N/m2 [0.54, 1.07]; SP: 1.08 N/m2 [0.74, 1.24]; VOL: 0.41 N/m2 [0.32, 0.60]; P ≤ 0.01) were increased in patients. One CP patient had a round aortic arch with physiological haemodynamic parameters.

CONCLUSIONS: The restoration of physiological aortic configuration and haemodynamics was not fully achieved with the curved prostheses in our study cohort. However, there was a tendency towards improved haemodynamic conditions in the patients with curved prostheses overall but without statistical significance. A single patient with a CP and near-physiological configuration of the thoracic aorta underlines the importance of optimizing postoperative geometric conditions for allowing for physiological haemodynamics and cardiovascular energetics after VSARR.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты