m+Medelevator.RU
← Поиск публикаций
The Journal of cardiovascular surgery · 2020

Sleeve valve-sparing procedure in bicuspid aortic valve: early and midterm clinical results.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tasca Giordano, Trinca Francesco, Riva Beatrice, Lobiati Elisabetta, Nasatti Andrea, Faccioli Paolo, Gamba Amando

Аннотация

BACKGROUND: Patients with aortic root ectasia and bicuspid aortic valve benefit of the treatment with aortic valve sparing procedure, with excellent long-term results. The Sleeve-procedure is one of the options in patients with aortic root diseases and it might be suitable for patients with a bicuspid valve.

METHODS: From October 2006 to December 2018, 42 consecutive patients with bicuspid aortic valve and aortic root ectasia/aneurysm, with or without aortic regurgitation, were surgically treated with the Sleeve-procedure.

RESULTS: In 20 patients (48%) leaflets surgery was necessary and consisted of raphe mobilization/resection in 17 patients, plication of both leaflets in 2 patients and a two-commissures resuspension in 1 patient. During a mean clinical follow-up time of 4.4±3.1 years, the survival rate was 100%, 1 patient required a reoperation at 6.1 years postoperatively, with an overall freedom from reoperation of 94±5%. The rest of the patients (41/42), had no more than mild residual aortic valve regurgitation. With a mean follow-up of 4.3±1.7 years the magnetic resonance imaging performed in 26 patients, did not show signs of aortic wall herniation through the key-holes or persisting creases of the aortic wall inside the prosthesis.

CONCLUSIONS: Patients with aortic root disease and bicuspid aortic valve may be treated with Sleeve technique with excellent midterm results. However, a longer follow-up is required before drawing any solid conclusion.

Предметные рубрики MeSH