BACKGROUND

The gold-standard approach to prosthesis sizing before transcatheter aortic valve implantation (TAVI) is multislice computed tomography (MSCT). We aimed to investigate whether conventional aortic root angiography (CA) alone can reliably facilitate valve selection and to describe its inter-reader variability.

METHODS

Five TAVI specialists (3 interventional cardiologists and 2 cardiac surgeons) independently reviewed preprocedural CAs for 50 patients implanted with the Edwards SAPIEN 3 valve.

RESULTS

The prosthesis size selected based on visual CA appraisal matched that based on MSCT in 60% of cases (range: 50%-68%), with undersizing in 11% (4%-33%) and oversizing in 29% (10%-46%; p=0.187 for equality of the proportions test). Agreement between CA-based and MSCT-based valve selection was moderate (K=0.41; Kw=0.61). Reassessment of choice following awareness of the annulus long-axis diameter did not significantly improve this agreement (0.40 and 0.63, respectively), though more undersizing (14%) and less oversizing (25%) occurred. Correct valve selection was more common in interventional cardiologists than cardiac surgeons (66% vs 53%; p=0.0391), who made more oversizing errors.

CONCLUSIONS

There is a modest agreement between CA-based and MSCT-based SAPIEN 3 selection. Although the former should not be performed routinely, it may be informative in settings where MSCT and transoesophageal echocardiography are unavailable.

Для цитирования: Gansera Laura, Ulm Bernhard, Bramlage Peter, Krapf Stephan, Oertel Frank, Mueller-Honold Tobias, von Scheidt Wolfgang, Thilo Christian. Utility of conventional aortic root shot angiography for SAPIEN 3 prosthesis sizing in TAVI: feasibility and inter-reader variability.. Open heart. 2019. DOI: 10.1136/openhrt-2019-001201.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.