Blood purification · 2023

Removal of α1-Microglobulin Using Post-Dilution Online Hemodiafiltration with Polymethylmethacrylate Membrane: An Open-Label, Single-Arm Study.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yoshida Shiori, Yamamoto Suguru, Miyauchi Daisuke, Terashima Ryohei, Hashimoto Atsushi, Miyazawa Haruna, Tanaka Takahiro, Ishizawa Masahiro, Tanaka Mototsugu, Tomita Yoshihiko, Aoike Ikuo, Goto Shin, Narita Ichiei

Аннотация

INTRODUCTION: The removal of low- and medium-molecular-weight proteins has been improved with online hemodiafiltration (OL-HDF) and hemodialysis using high-flux membranes; however, the outcomes of patients with end-stage kidney disease (ESKD) undergoing dialysis treatment are still worse than in the general population. α1-Microglobulin (α1-m), with a molecular weight of 33,000 Da, may contribute to dialysis-related disorders and mortality. However, the removal is insufficient even with current OL-HDF using the polysulfone (PS) membrane, which is common in Japan. Polymethylmethacrylate (PMMA) membranes can remove medium- to high-molecular-weight proteins by adsorption. This study aimed to assess the efficacy of removing medium- to high-molecular-weight proteins, such as α1-m and β2-microglobulin (β2-m), through post-dilution OL-HDF with PMMA (Post-PMMA). The assessment was conducted in comparison to pre-dilution OL-HDF with PS (Pre-PS), using an open-label, single-arm study.

METHODS: Seven patients with ESKD on Pre-PS underwent Post-PMMA with replacement volume of 30 mL/min (low flow) and 50 mL/min (high flow). Clearance and removal rates of α1-m, β2-m, small molecules, inflammatory cytokines, and albumin were measured at 60 and 240 min of treatment.

RESULTS: Clearance rates of α1-m at 60 min were -2.8 ± 5.2 mL/min with Pre-PS, -0.4 ± 2.6 mL/min with Post-PMMA (low), and 0.6 ± 3.4 mL/min with Post-PMMA (high). The removal rate of α1-m was higher in Post-PMMA than that in Pre-HDF-PS (Post-PMMA [high] 17.7 ± 5.9%, Post-PMMA [low] 15.0 ± 5.6%, and Pre-PS 4.1 ± 5.5%). Adsorption clearance of β2-m was increased with Post-PMMA. Albumin leakage in Post-PMMA was not higher than that in Pre-PS.

CONCLUSION: The removal rate of α1-m with Post-PMMA was higher than that with Pre-PS. The PMMA membrane adsorbed β2-m, suggesting the removal effect of medium- to high-molecular-weight proteins by the adsorption method. Since Post-PMMA effectively removes α1-m without excessive albumin leakage, it will be useful for patients with ESKD, especially those with a poor nutritional status.