Klinische Monatsblatter fur Augenheilkunde · 2019
Management of Anterior Chamber Dislocation of a Dexamethasone Implant.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Nguyen Thi Lyly, Wolfensberger Thomas J
Аннотация
PURPOSE: To characterise the surgical removal technique of a dislocated dexamethasone implant in the anterior chamber and to gauge its success by analysing corneal transparency and subsequent visual acuity recovery in the postoperative phase.
METHODS: Description of a patient who presented with an anterior chamber dexamethasone implant migration through an inferior iridotomy performed previously for a silicone oil fill in aphakia. Visual acuity had dropped to counting fingers due to marked corneal oedema.
RESULTS: The implant was removed using a 23-g needle aligned with the axis of the implant through a paracentesis. After the clinical follow-up at 2 months, best-corrected visual acuity had returned to 0.2, which remained stable at the last follow-up at 14 months with an intraocular pressure of 10 mmHg. The corneal oedema resolved completely.
CONCLUSION: This novel surgical management of a dexamethasone implant dislocation into the anterior chamber was successful and resulted in no long-term corneal damage when the implant was removed without delay. A repeated Ozurdex injection in patients with previous inferior iridotomy may require prior suturing of the iridotomy.
METHODS: Description of a patient who presented with an anterior chamber dexamethasone implant migration through an inferior iridotomy performed previously for a silicone oil fill in aphakia. Visual acuity had dropped to counting fingers due to marked corneal oedema.
RESULTS: The implant was removed using a 23-g needle aligned with the axis of the implant through a paracentesis. After the clinical follow-up at 2 months, best-corrected visual acuity had returned to 0.2, which remained stable at the last follow-up at 14 months with an intraocular pressure of 10 mmHg. The corneal oedema resolved completely.
CONCLUSION: This novel surgical management of a dexamethasone implant dislocation into the anterior chamber was successful and resulted in no long-term corneal damage when the implant was removed without delay. A repeated Ozurdex injection in patients with previous inferior iridotomy may require prior suturing of the iridotomy.