MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/adma.202411173

Медицинская библиотека · Advanced materials (Deerfield Beach, Fla.) · 2024

Bacteriophage-Activated DNAzyme Hydrogels Combined with Machine Learning Enable Point-of-Use Colorimetric Detection of Escherichia coli.

Mann Hannah, Khan Shadman, Prasad Akansha, Bayat Fereshteh, Gu Jimmy, Jackson Kyle, Li Yingfu, Hosseinidoust Zeinab, Didar Tohid F, Filipe Carlos D M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Developing cost-effective, consumer-accessible platforms for point-of-use environmental and clinical pathogen testing is a priority, to reduce reliance on laborious, time-consuming culturing approaches. Unfortunately, a system offering ultrasensitive detection capabilities in a form that requires little auxiliary equipment or training has remained elusive. Here, a colorimetric DNAzyme-crosslinked hydrogel sensor is presented. In the presence of a target pathogen, DNAzyme cleavage results in hydrogel dissolution, yielding the release of entrapped gold nanoparticles in a manner visible to the naked eye. Recognizing that Escherichia coli holds high relevance within both environmental and clinical environments, an E. coli-responsive DNAzyme is incorporated into this platform. Through the optimization of the hydrogel polymerization process and the discovery of bacteriophage-induced DNAzyme signal amplification, 101 CFU mL-1 E. coli is detected within real-world lake water samples. Subsequent pairing with an artificial intelligence model removed ambiguity in sensor readout, offering 96% true positive and 100% true negative accuracy. Finally, high sensor specificity and stability results supported clinical use, where 100% of urine samples collected from patients with E. coli urinary tract infections are accurately identified. No false positives are observed when testing healthy samples. Ultimately, this platform stands to significantly improve population health by substantially increasing pathogen testing accessibility.

Для цитирования: Mann Hannah, Khan Shadman, Prasad Akansha, Bayat Fereshteh, Gu Jimmy, Jackson Kyle, Li Yingfu, Hosseinidoust Zeinab, Didar Tohid F, Filipe Carlos D M. Bacteriophage-Activated DNAzyme Hydrogels Combined with Machine Learning Enable Point-of-Use Colorimetric Detection of Escherichia coli.. Advanced materials (Deerfield Beach, Fla.). 2024. DOI: 10.1002/adma.202411173.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.