MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjopen-2023-081398

Медицинская библиотека · BMJ open · 2024

Empowering Portable Age-Related Macular Degeneration Screening: Evaluation of a Deep Learning Algorithm for a Smartphone Fundus Camera.

Savoy Florian Mickael, Rao Divya Parthasarathy, Toh Jun Kai, Ong Bryan, Sivaraman Anand, Sharma Ashish, Das Taraprasad

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

OBJECTIVES

Despite global research on early detection of age-related macular degeneration (AMD), not enough is being done for large-scale screening. Automated analysis of retinal images captured via smartphone presents a potential solution; however, to our knowledge, such an artificial intelligence (AI) system has not been evaluated. The study aimed to assess the performance of an AI algorithm in detecting referable AMD on images captured on a portable fundus camera.

DESIGN,

SETTING

A retrospective image database from the Age-Related Eye Disease Study (AREDS) and target device was used.

PARTICIPANTS

The algorithm was trained on two distinct data sets with macula-centric images: initially on 108,251 images (55% referable AMD) from AREDS and then fine-tuned on 1108 images (33% referable AMD) captured on Asian eyes using the target device. The model was designed to indicate the presence of referable AMD (intermediate and advanced AMD). Following the first training step, the test set consisted of 909 images (49% referable AMD). For the fine-tuning step, the test set consisted of 238 (34% referable AMD) images. The reference standard for the AREDS data set was fundus image grading by the central reading centre, and for the target device, it was consensus image grading by specialists.

OUTCOME MEASURES: Area under receiver operating curve (AUC), sensitivity and specificity of algorithm.

RESULTS

Before fine-tuning, the deep learning (DL) algorithm exhibited a test set (from AREDS) sensitivity of 93.48% (95% CI: 90.8% to 95.6%), specificity of 82.33% (95% CI: 78.6% to 85.7%) and AUC of 0.965 (95% CI:0.95 to 0.98). After fine-tuning, the DL algorithm displayed a test set (from the target device) sensitivity of 91.25% (95% CI: 82.8% to 96.4%), specificity of 84.18% (95% CI: 77.5% to 89.5%) and AUC 0.947 (95% CI: 0.911 to 0.982).

CONCLUSION

The DL algorithm shows promising results in detecting referable AMD from a portable smartphone-based imaging system. This approach can potentially bring effective and affordable AMD screening to underserved areas.

Для цитирования: Savoy Florian Mickael, Rao Divya Parthasarathy, Toh Jun Kai, Ong Bryan, Sivaraman Anand, Sharma Ashish, Das Taraprasad. Empowering Portable Age-Related Macular Degeneration Screening: Evaluation of a Deep Learning Algorithm for a Smartphone Fundus Camera.. BMJ open. 2024. DOI: 10.1136/bmjopen-2023-081398.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.