m+Medelevator.RU
← Поиск публикаций
American journal of ophthalmology · 2019

A Deep Learning System for Automated Angle-Closure Detection in Anterior Segment Optical Coherence Tomography Images.

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Fu Huazhu, Baskaran Mani, Xu Yanwu, Lin Stephen, Wong Damon Wing Kee, Liu Jiang, Tun Tin A, Mahesh Meenakshi, Perera Shamira A, Aung Tin

Аннотация

PURPOSE: Anterior segment optical coherence tomography (AS-OCT) provides an objective imaging modality for visually identifying anterior segment structures. An automated detection system could assist ophthalmologists in interpreting AS-OCT images for the presence of angle closure.

DESIGN: Development of an artificial intelligence automated detection system for the presence of angle closure.

METHODS: A deep learning system for automated angle-closure detection in AS-OCT images was developed, and this was compared with another automated angle-closure detection system based on quantitative features. A total of 4135 Visante AS-OCT images from 2113 subjects (8270 anterior chamber angle images with 7375 open-angle and 895 angle-closure) were examined. The deep learning angle-closure detection system for a 2-class classification problem was tested by 5-fold cross-validation. The deep learning system and the automated angle-closure detection system based on quantitative features were evaluated against clinicians' grading of AS-OCT images as the reference standard.

RESULTS: The area under the receiver operating characteristic curve of the system using quantitative features was 0.90 (95% confidence interval [CI] 0.891-0.914) with a sensitivity of 0.79 ± 0.037 and a specificity of 0.87 ± 0.009, while the area under the receiver operating characteristic curve of the deep learning system was 0.96 (95% CI 0.953-0.968) with a sensitivity of 0.90 ± 0.02 and a specificity of 0.92 ± 0.008, against clinicians' grading of AS-OCT images as the reference standard.

CONCLUSIONS: The results demonstrate the potential of the deep learning system for angle-closure detection in AS-OCT images.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты