DOI 10.1111/j.1600-0536.2010.01772.x
Sensitization to contact allergens and bronchial hyper-responsiveness.
Аннотация
BACKGROUND
Exposure to contact allergens and specific allergic sensitization to them are common, but possible related health effects have been rarely studied.
OBJECTIVES
We aimed to analyse possible associations between contact sensitization to nickel sulfate and fragrance mix I and lung function parameters or bronchial hyper-responsiveness.
METHODS
Within a population-based study in Augsburg, 1052 adults performed lung function tests, including forced expiratory volume in 1 second (FEV(1)), forced vital capacity (FVC) and bronchial hyper-responsiveness (BHR). Patch tests were performed, and information was assessed by medical examinations and interviews. Logistic regression models were applied to study associations between contact allergies and lung function parameters.
RESULTS
Women were sensitized significantly more often than men to nickel [odds ratio (OR) 3.97, 95% confidence interval (CI) 2.50-6.29] and fragrance mix I (OR 2.28, 95% CI 1.50-3.46). Patch test results for nickel and fragrance mix I did not influence mean FEV(1) and FVC % predicted values. However, in women, a higher rate of BHR was associated with positive patch test reactions to fragrance mix I (OR 2.24, 95% CI 1.11-4.52).
CONCLUSIONS
Contact sensitization to fragrance mix I is associated with a higher rate of BHR in women. Thus, in women with contact allergy to fragrances, airway obstruction should be considered as a possible co-morbidity.