MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.media.2024.103256

Медицинская библиотека · Medical image analysis · 2024

Deblurring masked image modeling for ultrasound image analysis.

Kang Qingbo, Lao Qicheng, Gao Jun, Liu Jingyan, Yi Huahui, Ma Buyun, Zhang Xiaofan, Li Kang

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Recently, large pretrained vision foundation models based on masked image modeling (MIM) have attracted unprecedented attention and achieved remarkable performance across various tasks. However, the study of MIM for ultrasound imaging remains relatively unexplored, and most importantly, current MIM approaches fail to account for the gap between natural images and ultrasound, as well as the intrinsic imaging characteristics of the ultrasound modality, such as the high noise-to-signal ratio. In this paper, motivated by the unique high noise-to-signal ratio property in ultrasound, we propose a deblurring MIM approach specialized to ultrasound, which incorporates a deblurring task into the pretraining proxy task. The incorporation of deblurring facilitates the pretraining to better recover the subtle details within ultrasound images that are vital for subsequent downstream analysis. Furthermore, we employ a multi-scale hierarchical encoder to extract both local and global contextual cues for improved performance, especially on pixel-wise tasks such as segmentation. We conduct extensive experiments involving 280,000 ultrasound images for the pretraining and evaluate the downstream transfer performance of the pretrained model on various disease diagnoses (nodule, Hashimoto's thyroiditis) and task types (classification, segmentation). The experimental results demonstrate the efficacy of the proposed deblurring MIM, achieving state-of-the-art performance across a wide range of downstream tasks and datasets. Overall, our work highlights the potential of deblurring MIM for ultrasound image analysis, presenting an ultrasound-specific vision foundation model.

Для цитирования: Kang Qingbo, Lao Qicheng, Gao Jun, Liu Jingyan, Yi Huahui, Ma Buyun, Zhang Xiaofan, Li Kang. Deblurring masked image modeling for ultrasound image analysis.. Medical image analysis. 2024. DOI: 10.1016/j.media.2024.103256.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.