The Annals of thoracic surgery · 2015
The Expanding Role of Endoscopic Robotics in Mitral Valve Surgery: 1,257 Consecutive Procedures.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Murphy Douglas A, Moss Emmanuel, Binongo Jose, Miller Jeffrey S, Macheers Steven K, Sarin Eric L, Herzog Alexander M, Thourani Vinod H, Guyton Robert A, Halkos Michael E
Аннотация
BACKGROUND: The role of robotic instruments in mitral valve (MV) surgery continues to evolve. The purpose of this study was to assess the safety, efficacy, and scope of MV surgery using a lateral endoscopic approach with robotics (LEAR) technique.
METHODS: From 2006 to 2013, a dedicated LEAR team performed 1,257 consecutive isolated MV procedures with or without tricuspid valve repair or atrial ablation. The procedures were performed robotically through five right-side chest ports with femoral artery or ascending aortic perfusion and balloon occlusion. Operative videos and data were recorded on all procedures and reviewed retrospectively.
RESULTS: The mean age of all patients was 59.3 ± 20.5 years, and 8.4% (n = 105) had previous cardiac surgery. The MV repair was performed in 1,167 patients (93%). The MV replacement was performed in 88 patients (7%), and paravalvular leak repair in 2 patients. Concomitant atrial ablation was performed in 226 patients (18%), and tricuspid valve repair in 138 patients (11%). Operative mortality occurred in 11 patients (0.9%) and stroke in 9 patients (0.7%). Predischarge echocardiograms demonstrated mild or less mitral regurgitation in 98.3% of MV repair patients. At mean follow-up of 50 ± 26 months, 44 patients (3.8%) required MV reoperation. Application of the LEAR technique to all institutional isolated MV procedures increased from 46% in the first year to more than 90% in the last 3 years.
CONCLUSIONS: Mitral valve repair or replacement, including concomitant procedures, can be performed safely and effectively using the LEAR technique. With a dedicated robotic team, the vast majority of patients with MV disorders, either isolated or with concomitant problems, can be treated using the LEAR technique.
METHODS: From 2006 to 2013, a dedicated LEAR team performed 1,257 consecutive isolated MV procedures with or without tricuspid valve repair or atrial ablation. The procedures were performed robotically through five right-side chest ports with femoral artery or ascending aortic perfusion and balloon occlusion. Operative videos and data were recorded on all procedures and reviewed retrospectively.
RESULTS: The mean age of all patients was 59.3 ± 20.5 years, and 8.4% (n = 105) had previous cardiac surgery. The MV repair was performed in 1,167 patients (93%). The MV replacement was performed in 88 patients (7%), and paravalvular leak repair in 2 patients. Concomitant atrial ablation was performed in 226 patients (18%), and tricuspid valve repair in 138 patients (11%). Operative mortality occurred in 11 patients (0.9%) and stroke in 9 patients (0.7%). Predischarge echocardiograms demonstrated mild or less mitral regurgitation in 98.3% of MV repair patients. At mean follow-up of 50 ± 26 months, 44 patients (3.8%) required MV reoperation. Application of the LEAR technique to all institutional isolated MV procedures increased from 46% in the first year to more than 90% in the last 3 years.
CONCLUSIONS: Mitral valve repair or replacement, including concomitant procedures, can be performed safely and effectively using the LEAR technique. With a dedicated robotic team, the vast majority of patients with MV disorders, either isolated or with concomitant problems, can be treated using the LEAR technique.