OBJECTIVE

The diagnosis of paresis in patients with vocal fold motion impairment remains a challenge. In particular, laryngoscopy examination may result in significant disagreement in diagnosis among providers. We hypothesize that systematically evaluating for a standard set of clinical parameters will increase the diagnostic concordance among providers.

STUDY

DESIGN

Prospective case series conducted at a Tertiary referral Laryngology office.

METHODS

Two laryngologists (rater 1) and two trainees (rater 2) rated laryngoscopy findings in 19 patients suspected of paresis. The diagnosis was confirmed with laryngeal electromyogram. A standard set of 27 ratings was used for each examination that included movement, laryngeal configuration, and stroboscopy signs. A kappa coefficient was calculated for agreement in laryngoscopy findings and effectiveness in predicting the laterality of paresis.

RESULTS

A substantial agreement (kappa coefficient > 0.61) existed between the raters for vocal fold length, vocal fold thickness, bowing, and reduction in movement. A moderate agreement (kappa coefficient > 0.41) existed between raters for piriform opening and reduced kinesis. The senior author was accurately able to diagnose the side of paresis in 89.5% of cases for a kappa coefficient of 0.78, whereas the trainees correctly predicted the side of paresis in 63.1% for a kappa coefficient of 0.35. The raters agreed on the diagnosis in 73.7% of cases for a kappa coefficient of 0.50.

CONCLUSIONS

Using a standard set of laryngoscopy findings may improve the provider's ability to identify the laterality of vocal fold paresis and increase interrater reliability compared with other series.

Для цитирования: Isseroff Tova F, Parasher Arjun K, Richards Amanda, Sivak Mark, Woo Peak. Interrater Reliability in Analysis of Laryngoscopic Features for Unilateral Vocal Fold Paresis.. Journal of voice : official journal of the Voice Foundation. 2015. DOI: 10.1016/j.jvoice.2015.08.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.