m+Medelevator.RU
← Поиск публикаций
Veterinary ophthalmology · 2015

Novel retinopathy in related Gordon setters: a clinical, behavioral, electrophysiological, and genetic investigation.

Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Good Kathryn L, Komáromy András M, Kass Philip H, Ofri Ron

Аннотация

PURPOSE: To conduct ophthalmic, behavioral, electrophysiological, and genetic testing on two related Gordon setters presented for day blindness and compare findings with those of nine related and unrelated Gordon setters.

METHODS: All dogs underwent comprehensive ophthalmic examination. Maze testing was conducted under different light intensities. Rod and cone function was assessed electroretinographically. DNA samples were screened for five canine retinal disease gene mutations.

RESULTS: Ophthalmic examination was unremarkable in all dogs. There was no notable difference between day blind dogs and the reference population in scotopic and mesopic maze tests. Day blind dogs performed worse in the photopic maze with slower course completion time and more obstacle collisions. Electroretinography revealed extinguished cone function in day blind dogs and depressed rod responses in all but two reference dogs. One reference population dog presented with day blindness 1 year after initial examination. Mutations that cause achromatopsia (in CNGB3) and cone-rod dystrophies (in ADAM9 and IQCB1) were not detected in any dog tested, although five reference dogs were carriers of the mutation in C2orf71 that causes rod-cone degeneration 4 (rcd4) in Gordon setters and in polski owczarek nizinny dogs.

CONCLUSIONS: This report describes a novel retinopathy in related Gordon setters that has clinical signs and vision testing results consistent with achromatopsia but electroretinographic results suggestive of cone-rod dystrophy. The majority of Gordon setters in this study had low rod responses on electroretinography but it is unclear whether this was indicative of rod dysfunction or normal for the breed. Longer-term observation of affected individuals is warranted.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты