Infradentate Approach to the Fourth Ventricle.

Jamshidi Ali O, Priddy Blake, Beer-Furlan Andre, Prevedello Daniel M

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The use of minimally invasive transcranial ports for the resection of deep-seated lesions has been shown to be safe and effective for supratentorial lesions. The routine use of this surgical modality for posterior fossa masses has not been well established in the literature. In particular, fourth ventricular tumors are not the typical target for neuro-port surgery because of potential injury to the dentate nucleus.

OBJECTIVE

To describe the use of a tubular retractor system to reach the fourth ventricle while sparing the cerebellar vermis and the dentate nucleus. Three cases illustrations are presented.

METHODS

Surgical access to the fourth ventricle was developed sparing the cerebellar vermis and the dentate nucleus. The authors reviewed 3 cases to illustrate the feasibility of minimal access transcerebellar port surgery for the resection of these lesions using an infradentate access.

RESULTS

None of the patients developed new neurological deficits and the pathology was successfully resected in all cases. There were no major complications related to surgery and no mortalities.

CONCLUSION

The infradentate approach obviates the need for traditional approaches to the fourth ventricle, thus making this challenging target in the posterior fossa more accessible to neurosurgeons. The authors observed successful removal of lesions involving the fourth ventricle while avoiding any associated morbidity or mortality.

Для цитирования: Jamshidi Ali O, Priddy Blake, Beer-Furlan Andre, Prevedello Daniel M. Infradentate Approach to the Fourth Ventricle.. Operative neurosurgery (Hagerstown, Md.). 2019. DOI: 10.1093/ons/opy175.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.