MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1182/blood-2010-09-307637

Медицинская библиотека · Blood · 2011

Vitamin C is dispensable for oxygen sensing in vivo.

Nytko Katarzyna J, Maeda Nobuyo, Schläfli Philipp, Spielmann Patrick, Wenger Roland H, Stiehl Daniel P

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Prolyl-4-hydroxylation is necessary for proper structural assembly of collagens and oxygen-dependent protein stability of hypoxia-inducible transcription factors (HIFs). In vitro function of HIF prolyl-4-hydroxylase domain (PHD) enzymes requires oxygen and 2-oxoglutarate as cosubstrates with iron(II) and vitamin C serving as cofactors. Although vitamin C deficiency is known to cause the collagen-disassembly disease scurvy, it is unclear whether cellular oxygen sensing is similarly affected. Here, we report that vitamin C-deprived Gulo(-/-) knockout mice show normal HIF-dependent gene expression. The systemic response of Gulo(-/-) animals to inspiratory hypoxia, as measured by plasma erythropoietin levels, was similar to that of animals supplemented with vitamin C. Hypoxic HIF induction was also essentially normal under serum- and vitamin C-free cell-culture conditions, suggesting that vitamin C is not required for oxygen sensing in vivo. Glutathione was found to fully substitute for vitamin C requirement of all 3 PHD isoforms in vitro. Consistently, glutathione also reduced HIF-1α protein levels, transactivation activity, and endogenous target gene expression in cells exposed to CoCl(2). A Cys201Ser mutation in PHD2 increased basal hydroxylation rates and conferred resistance to oxidative damage in vitro, suggesting that this surface-accessible PHD2 cysteine residue is a target of antioxidative protection by vitamin C and glutathione.

Для цитирования: Nytko Katarzyna J, Maeda Nobuyo, Schläfli Philipp, Spielmann Patrick, Wenger Roland H, Stiehl Daniel P. Vitamin C is dispensable for oxygen sensing in vivo.. Blood. 2011. DOI: 10.1182/blood-2010-09-307637.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.