OBJECTIVE

To investigate the reasons for the weak expression of RHCE gene in a patient whose mimicking anti-Ce combined with anti-Jkb caused cross-matching non-combination.

METHODS

ABO, Rh, and Kidd blood group antigens were identified by test tube method and capillary centrifugation. Antibody screening and antibody specificity identification were performed using saline, polybrene and antiglobulin in tri-media association with multispectral cells. RHCE gene sequencing and haploid analysis were performed by multiplex PCR technique and RHCE protein modeling was performed using Swiss-Model.

RESULTS

The serum of the patient contained anti-Ce mimicking autoantibodies along with anti-Jkb antibodies. c.48G>C, c.150C>T, c.178C>A, c.201A>G, c.203A>G, and c.307C>T mutations were detected in the RHCE triple-molecule sequencing. A 109 bp insertion sequence was found in intron 2, with fragment loss from intron 5-8. The Rh-group genotype was DCe/DCe , and phenotype was CCDee.

CONCLUSION

Genotyping techniques can assist in deducing the molecular mechanisms of some weakly expressed RhC, c, E, and e in patients' sera to aid in the identification of difficult antibodies and thus ensure the safety of patients' blood transfusion.

Для цитирования: Yang Hong-Mei, Yu Xi, Zou Xin, Ma Si-Fei, Chen Jin, Zhang Jian-Wei. [Analysis of RhC Antigen Weak Expression Combined with Mimicking Autoanti-Ce and Homologous Anti-Jkb Causing Mismatch].. Zhongguo shi yan xue ye xue za zhi. 2024. DOI: 10.19746/j.cnki.issn.1009-2137.2024.05.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.