MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.leukres.2022.106953

Медицинская библиотека · Leukemia research · 2022

Effect of clinical application of anti-CD38 and anti-CD47 monoclonal antibodies on blood group detection and transfusion therapy and treatment.

Du Chunhong, Sui Weijia, Huang Haitao, Zhang Yuan, Ding Xin, Gao Cuicui, Wang Yihao

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

To investigate the effect of anti-CD38 monoclonal antibodies (mAb) (daratumumab, DARA) and anti-CD47 mAb combined with azacytidine on blood transfusion compatibility tests, transfusion effects in the treatment of multiple myeloma or acute myeloid leukemia and the corresponding management strategy.

MATERIALS AND

METHODS

Among the 19 patients who were treated with DARA and anti-CD47 mAb, 4 patients with cross matching incompatibility were selected. The ABO blood group, the Rh blood group, irregular antibody screening and direct antiglobulin test (DAT) and cross matching testing were performed before and after the application of mAbs using serological methods. Then, irregular antibody screening and microcolumn gel cross matching tests were performed with donor and recipient erythrocytes and serum treated with DL-dithiothreitol (DTT) and Immucor kit, respectively. The transfusion effect was monitored.

RESULTS

21.05% (4/19) patients had mismatched cross-matching results after mAb treatment. The agglutination intensity of irregular antibody screening tests (3 + ∼ 4 +) after anti-CD47 mAb was higher than that (1 + ∼ 2 +) after DARA. In the DARA group, treating RBCs with 0.2 mol L-1 DTT eliminated the DARA interference with antibody screening. In the anti-CD47 mAb group, the antibody screening, cross-matching test and DAT had been strongly interfered, and using Immucor kit eliminated the interference with antibody screening testing. There was no difference in the transfusion effect.

CONCLUSION

The application of mAb drugs led to incompatibility of cross matching tests, and the transfusion effect was not affected.

Для цитирования: Du Chunhong, Sui Weijia, Huang Haitao, Zhang Yuan, Ding Xin, Gao Cuicui, Wang Yihao. Effect of clinical application of anti-CD38 and anti-CD47 monoclonal antibodies on blood group detection and transfusion therapy and treatment.. Leukemia research. 2022. DOI: 10.1016/j.leukres.2022.106953.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.