DOI 10.1111/j.1444-0938.2011.00631.x
Central corneal thickness in patients with meibomian gland dysfunction.
Аннотация
PURPOSE: The aim was to evaluate central corneal thickness in patients with meibomian gland dysfunction.
METHODS
The study group was made up of 40 eyes of 20 patients with meibomian gland dysfunction (mean age, 40.55 ± 10.7 years). Forty eyes of 20 healthy individuals (mean age, 39.25 ± 11.1 years) without any ophthalmic or systemic pathology were used as a control group. The central corneal thickness was measured with ultrasonic pachymetry.
RESULTS
The mean central corneal thickness was 541.45 ± 24.68 µm in the study group and 544.30 ± 22.16 µm in the control group. There was no statistically significant difference in the mean central corneal thickness measurements in the meibomian gland dysfunction group in comparison with the control group (p > 0.05).
CONCLUSION
Central corneal thickness measurements do not differ in patients with meibomian gland dysfunction compared with healthy control subjects.