MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1444-0938.2011.00631.x

Медицинская библиотека · Clinical & experimental optometry · 2011

Central corneal thickness in patients with meibomian gland dysfunction.

Akyol-Salman Ilknur, Azizi Sedat, Mumcu Uğur, Öndaş Osman, Baykal Orhan

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The aim was to evaluate central corneal thickness in patients with meibomian gland dysfunction.

METHODS

The study group was made up of 40 eyes of 20 patients with meibomian gland dysfunction (mean age, 40.55 ± 10.7 years). Forty eyes of 20 healthy individuals (mean age, 39.25 ± 11.1 years) without any ophthalmic or systemic pathology were used as a control group. The central corneal thickness was measured with ultrasonic pachymetry.

RESULTS

The mean central corneal thickness was 541.45 ± 24.68 µm in the study group and 544.30 ± 22.16 µm in the control group. There was no statistically significant difference in the mean central corneal thickness measurements in the meibomian gland dysfunction group in comparison with the control group (p > 0.05).

CONCLUSION

Central corneal thickness measurements do not differ in patients with meibomian gland dysfunction compared with healthy control subjects.

Для цитирования: Akyol-Salman Ilknur, Azizi Sedat, Mumcu Uğur, Öndaş Osman, Baykal Orhan. Central corneal thickness in patients with meibomian gland dysfunction.. Clinical & experimental optometry. 2011. DOI: 10.1111/j.1444-0938.2011.00631.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.