OBJECTIVES

Our goal was to assess the aortic leaflet free margin length (FML) and geometric height (gH) in a normal aortic valve (AV), aorta dilatation and aortic leaflet prolapse.

METHODS

We measured the FML and gH intraoperatively in 132 patients operated on for aortic insufficiency, aortic dilatation, endocarditis or fibroelastoma. Patients were divided into 3 groups: normal tricuspid AV (group 1, n = 12), aortic dilatation (group 2, tricuspid = 43, bicuspid = 18) and leaflet prolapse (group 3, tricuspid = 32, bicuspid = 27). The FML and gH were compared between the groups and between the leaflets within each group.

RESULTS

In a normal tricuspid AV, the mean FML and gH were 34.7 ± 3.1 mm and 18.8 ± 1.7 mm, respectively. In group 2 tricuspid, the FML and gH were greater than those in group 1 (FML 43.7 ± 4.4, P < 0.001; gH 21.2 ± 1.8, P = 0.003). In group 3, tricuspid, the FML of the prolapsing leaflet was greater than the FML of the non-prolapsing leaflet (48.3 ± 5.4 vs 42.2 ± 3.6; P < 0.001). In group 2, bicuspid, FML of both leaflets were similar in group 2, but augmented on the fused leaflet compared to the non-fused leaflet in group 3 (fused 55.4 ± 6.3; non-fused 46.2 ± 6.2; P < 0.001). In groups 2 and 3 bicuspid, the gH of the non-fused leaflet was systematically greater than the fused leaflet (group 2 non-fused 24.6 ± 2.5 vs fused 20.4 ± 2.1; P < 0.001).

CONCLUSIONS

In aortic dilatation and leaflet prolapse, FML and, to a lesser extent, gH increased significantly compared to those of normal AV function. FML and gH dimensions also depended on the valve configuration (tricuspid/bicuspid). These data provide new insight into the pathomorphology of AV disease and will serve to further develop new methods of AV repair based on intraoperative measurements of the FML.

Для цитирования: Tamer Saadallah, Mastrobuoni Stefano, van Dyck Michel, Navarra Emiliano, Bollen Xavier, Poncelet Alain, Noirhomme Philippe, Astarci Parla, El Khoury Gebrine, de Kerchove Laurent. Free margin length and geometric height in aortic root dilatation and leaflet prolapse: implications for aortic valve repair surgery.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2020. DOI: 10.1093/ejcts/ezz132.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.