Implications of Asymmetry and Valvular Morphotype on Echocardiographic Measurements of the Aortic Root in Bicuspid Aortic Valve.

Vis Jeroen C, Rodríguez-Palomares Jose F, Teixidó-Tura Gisela, Galian-Gay Laura, Granato Chiara, Guala Andrea, Sao-Aviles Augusto, Gutiérrez Laura, González-Alujas Teresa, García-Dorado David, Evangelista Arturo

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Transthoracic echocardiography (TTE) and magnetic resonance imaging (MRI) have yielded excellent results in aortic root diameter measurement in patients with tricuspid aortic valve. However, accuracy in bicuspid aortic valve (BAV), often associated with aortic root asymmetry, is not fully defined. The aim of this study was to determine the agreement between TTE and MRI in proximal ascending aortic diameters in patients with BAVs.

METHODS

Seventy-six consecutive patients with BAVs (mean age, 53 ± 15 years; 65% men) who underwent both TTE and MRI for ascending aortic assessment in a follow-up protocol were included in the study. Maximum aortic root and ascending aortic diameters were compared.

RESULTS

For the whole population, TTE slightly underestimated aortic root diameter (difference, -0.8 ± 2.9 mm; P = .02). However, agreement was significantly better in BAV with fusion of the left and right coronary cusps than with fusion of the right coronary and noncoronary cusps, both with (type 1) and without (type 0) raphe (mean difference, 0.1 ± 2.5 vs -2.8 ± 2.8 mm, P < .001, respectively). In raphe BAV, mean absolute differences of maximum diameters between both techniques were significantly greater in asymmetric versus symmetric aortic roots (3.3 ± 2.2 vs 1.6 ± 1.9 mm, P = .002). BAV type and root asymmetry were independent related to measurement disagreement between both modalities.

CONCLUSIONS

Although TTE is the technique of choice in the follow-up of patients with BAVs, aortic root diameter measurements may be inaccurate in the presence of root asymmetry and in BAV with fusion of the right coronary and noncoronary cusps. In these cases, cross-sectional imaging, with MRI or computed tomography, to confirm aortic diameters may be advisable.

Для цитирования: Vis Jeroen C, Rodríguez-Palomares Jose F, Teixidó-Tura Gisela, Galian-Gay Laura, Granato Chiara, Guala Andrea, Sao-Aviles Augusto, Gutiérrez Laura, González-Alujas Teresa, García-Dorado David, Evangelista Arturo. Implications of Asymmetry and Valvular Morphotype on Echocardiographic Measurements of the Aortic Root in Bicuspid Aortic Valve.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2018. DOI: 10.1016/j.echo.2018.08.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.