MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-024-68524-2

Медицинская библиотека · Scientific reports · 2024

Development and evaluation of a real-time multienzyme isothermal rapid amplification assay for rapid detection of Streptococcus pneumoniae.

Xing Yun, Duan Zhixiong, Jiang Yuansu, Li Min, Lu Weiping, Li Jin

СтатьяОценочное исследованиеПеревод пока не подготовлен

Аннотация

Streptococcus pneumoniae is a significant pathogen causing infectious diseases, including pneumonia, otitis media, septicemia, and meningitis. The introduction of multivalent vaccines has coincided with a remarkable decrease in the number of pneumococcal-related deaths. Despite this, pneumococcal infection remains a significant cause of death among children under 5 years old and adults aged 65 or older at a global level. Therefore, early detection of S. pneumoniae infection is crucial for prognosis of pneumococcal infection patients. In this study, we evaluated the utility of a real-time multienzyme isothermal rapid amplification (MIRA) assay for detecting S. pneumoniae and other non-S. pneumoniae bacterial species. A primer-probe set targeting the S. pneumoniae lytA gene was designed, followed by optimization of parameters for the MIRA assay. At the same time, we validated the real-time MIRA assay for detecting S. pneumoniae using 79 clinical isolates identified by VITEK MS. The results showed a detection sensitivity and specificity of 100%. These results demonstrate that the designed real-time MIRA assay is a promising, rapid, simple, and reliable method for detecting S. pneumoniae infection in resource-limited areas. It has great potential for application in detecting not only S. pneumoniae but also other non-S. pneumoniae bacterial species.

Для цитирования: Xing Yun, Duan Zhixiong, Jiang Yuansu, Li Min, Lu Weiping, Li Jin. Development and evaluation of a real-time multienzyme isothermal rapid amplification assay for rapid detection of Streptococcus pneumoniae.. Scientific reports. 2024. DOI: 10.1038/s41598-024-68524-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.