Diagnostic value of blink reflex in multisystem atrophy, progressive supranuclear palsy and Parkinson disease.

Szmidt-Salkowska Elzbieta, Gawel Malgorzata, Jamrozik Zygmunt, Salkowska-Wanat Joanna, Gawel Damian, Kaminska Anna

СтатьяПеревод пока не подготовлен

Аннотация

UNLABELLED: Abnormal blink reflex (BR) is a result of reticular brainstem pathways dysfunction and seems to be one of the features of brain degenerative disorders. The aim of the study was to estimate the diagnostic value of blink reflex in neurodegenerative diseases such as: multisystem atrophy (MSA), progressive supranuclear palsy (PSP) and Parkinson disease (PD). Material consisted of 99 patients with clinically probable MSA (51), PSP (28) and PD (20). MSA patients were divided into two subgroups, with dominant cerebellar (MSA-C) and parkinsonian signs (MSA-P). The mean age of patients was 64.9 years (47-79 years); males - 55.3%. Blink reflex was obtained in a typical way.

RESULTS

The significant differences in mean values of blink reflex latencies between PD and other subgroups (MSA-P, MSA-C, PSP) were found, but all of them were in normal range. In individual patients with PD and PSP (50% and 18%, respectively) delayed R2 latencies were recorded.

CONCLUSIONS

The most frequently abnormal blink reflexes, comparing the MSA, PSP and PD groups, were present in PD patients. We postulate that this may be explained by pathological influence of nigrostriatal pathway on the circuit linking the basal ganglia, cerebellum and brainstem.

Для цитирования: Szmidt-Salkowska Elzbieta, Gawel Malgorzata, Jamrozik Zygmunt, Salkowska-Wanat Joanna, Gawel Damian, Kaminska Anna. Diagnostic value of blink reflex in multisystem atrophy, progressive supranuclear palsy and Parkinson disease.. Neurologia i neurochirurgia polska. 2016. DOI: 10.1016/j.pjnns.2016.06.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.