Phakic intraocular lens: Two-year results and comparison of endothelial cell loss with iris-fixated intraocular lenses.

Aerts Andreas A S, Jonker Soraya M R, Wielders Laura H P, Berendschot Tos T J M, Doors Muriël, De Brabander John, Nuijts Rudy M M A

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the efficacy, safety, and stability of a foldable angle-supported Acrysof Cachet phakic intraocular lens (pIOL) to correct moderate to high myopia and compare endothelial cell loss after iris-fixated Artisan and Artiflex pIOL implantation.

SETTING

University Eye Clinic Maastricht, the Netherlands.

DESIGN

Retrospective observational study.

METHODS

Foldable angle-supported pIOL implantation for myopia ranging from -6.0 to -16.5 diopters (D) was done. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, spherical equivalent (SE), and adverse events were documented preoperatively and 6 months and 1 and 2 years postoperatively. Endothelial cell loss after implantation of the foldable angle-supported pIOL and iris-fixated pIOLs was compared 6 months and 1 and 2 years postoperatively.

RESULTS

There were 158 eyes. The UDVA was equal to or more than 20/25 in 95% of eyes at 1 and 2 years postoperatively. The mean SE was -0.17 D ± 0.43 (SD) 2 years postoperatively. One patient developed pupil ovalization, resulting in explantation of the pIOL from both eyes. Acute endothelial cell loss in the foldable angle-supported pIOL group was -3.2% ± 0.7%, significantly higher than after iris-fixated pIOL implantation. Chronic endothelial cell loss from 6 to 24 months after surgery was -3.8% ± 0.7%. At the 2-year follow-up, the chronic endothelial cell loss in the foldable angle-supported pIOL group was not different than with iris-fixated pIOLs (P > .05).

CONCLUSIONS

The foldable angle-supported pIOL effectively corrected moderate to high myopia. However, acute surgical endothelial cell loss was significantly higher than with iris-fixated pIOLs.

FINANCIAL DISCLOSURE: Dr. Nuijts is a consultant to Alcon Laboratories, Inc., Théa Pharma GmbH, and ASICO LLC; he has received study grants from Acufocus, Inc., Alcon Laboratories, Inc., Carl Zeiss Meditec AG, Ophtec BV, and Physiol S.A. No other author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: Aerts Andreas A S, Jonker Soraya M R, Wielders Laura H P, Berendschot Tos T J M, Doors Muriël, De Brabander John, Nuijts Rudy M M A. Phakic intraocular lens: Two-year results and comparison of endothelial cell loss with iris-fixated intraocular lenses.. Journal of cataract and refractive surgery. 2015. DOI: 10.1016/j.jcrs.2015.10.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.