MedElevator Войти в исследования
← Поиск публикаций

DOI 10.14744/tjtes.2023.86579

Медицинская библиотека · Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES · 2023

The comparison of the suture materials on intestinal anastomotic healing: an experimental study.

Uzunlu Osman, Aydin Emrah, Çomut Erdem, Avcı Esin, Şenol Hande

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

This experimental comparative study was to evaluate the local effects of three different suture materials on in-testinal anastomosis healing.

METHODS

Ethical approval was obtained from the University of Ethical Committee (E-60758568-020-176720). A prospective, experimental comparative analysis was conducted on 24 rats. They were divided into three equal groups; Group 1 underwent colonic anastomosis with Vicryl suture material, Group 2 underwent colonic anastomosis with polypropylene suture; and Group 3 underwent colonic anastomosis with polydioxanone (PDS) suture. The second operation underwent the 7th post-operative day. Adhesion score, anastomotic leakage, anastomotic bursting pressure, hydroxyproline levels, and histopathologic examination were evaluated.

RESULTS

All animals survived, and no leakage, intestinal obstruction, or wound infection was observed during the experiment. The adhesion score was evaluated according to the Diamond classification and same in all groups. Median anastomotic bursting pressure was 125.75 mmHg (10-241) in the Vicryl group, 159.25 mmHg (113-190) in the polypropylene group, and 154.50 mmHg (20-212) in the PDS group. Hydroxyproline tissue concentrations were in the Vicryl group 1699.92±220.8 ng/mg (range: 1509.81-2186.47), in the polypropylene group 1126.24±607.12 ng/mg (range: 53.22-1815.63), and 1547.86±335.2 ng/mg (range: 973.66-1973.2) in PDS group. There was no difference among groups regarding the inflammatory response evaluated by histopathology. There was no statistical significance in all variables evaluated.

CONCLUSION

This experimental study demonstrates that suture materials did not worsen tissue healing during intestinal anastomosis. Absorbable, slowly-absorbable, and non-absorbable suture materials could be used safely in every situation.

Для цитирования: Uzunlu Osman, Aydin Emrah, Çomut Erdem, Avcı Esin, Şenol Hande. The comparison of the suture materials on intestinal anastomotic healing: an experimental study.. Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES. 2023. DOI: 10.14744/tjtes.2023.86579.