Leung Kitty, Louca Emily, Munson Keith, Dutzar Benjamin, Anklesaria Pervin, Coates Allan L
Аннотация
BACKGROUND: Cystic fibrosis is an autosomal recessive disease affecting approximately 1 in 2500 live births. Introducing the cDNA that codes for normal cystic fibrosis transmembrane conductance regulator (CFTR) to the small airways of the lung could result in restoring the CFTR function. A number of vectors for lung gene therapy have been tried and adeno-associated virus (AAV) vectors offer promise. The vector is delivered to the lung using a breath-actuated jet nebulizer. The purpose of this project was to determine the aerosolized AAV (tgAAVCF) particle size distribution (PSD) in order to calculate target doses for lung delivery.
METHODS: A tgAAVCF solution was nebulized using the Pari LC Plus (n = 3), and the PSD was determined by coupling laser diffraction and inertial impaction (NGI) techniques. The NGI allowed for quantification of the tgAAVCF at each stage of impaction, ensuring that rAAV-CFTR vector is present and not empty particles. Applying the results to mathematical algorithms allowed for the calculation of expected pulmonary deposition.
RESULTS: The mass median diameter (MMD) for the tgAAVCF was 2.78 +/- 0.43 microm. If the system works ideally and the patient only receives aerosol on inspiration, the patient would receive 47 +/- 0% of the initial dose placed in the nebulizer, with 72 +/- 0.73% of this being deposited beyond the vocal cords.
CONCLUSIONS: This technology for categorizing the pulmonary delivery system for lung gene therapy vectors can be adapted for advanced aerosol delivery systems or other vectors.
METHODS: A tgAAVCF solution was nebulized using the Pari LC Plus (n = 3), and the PSD was determined by coupling laser diffraction and inertial impaction (NGI) techniques. The NGI allowed for quantification of the tgAAVCF at each stage of impaction, ensuring that rAAV-CFTR vector is present and not empty particles. Applying the results to mathematical algorithms allowed for the calculation of expected pulmonary deposition.
RESULTS: The mass median diameter (MMD) for the tgAAVCF was 2.78 +/- 0.43 microm. If the system works ideally and the patient only receives aerosol on inspiration, the patient would receive 47 +/- 0% of the initial dose placed in the nebulizer, with 72 +/- 0.73% of this being deposited beyond the vocal cords.