Efficacy and safety of the SoniCracker intravascular lithotripsy device for severely calcified coronary lesions: the LEAD-FIM study from China.

СтатьяМногоцентровое исследованиеКлиническое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Liu Haiwei, Xiu Jiancheng, Qin Qin, Bai Ziliang, Tong Qian, Jia Shaobin, Zhang Ping, Zhang Jun, Zhong Zhixiong, Liu Wei, He Yong, Jing Quanmin, Han Yaling

Аннотация

BACKGROUND: Calcified lesions represent a key challenge in percutaneous coronary intervention (PCI). In recent years, intravascular lithotripsy (IVL) has emerged as a safe and effective adjunctive therapy for severely calcified lesions before stenting implantation. In the present study, we investigated the safety and efficacy of a novel coronary IVL system in patients with severely calcified lesions. METHODS: The LEAD-FIM study was a prospective, multicenter, single-arm trial in China. Patients with severely calcified lesions and a clinical indication for PCI with vessel preparation for DES implantation using IVL. The primary endpoint was procedural success, which was defined as residual stenosis ≤ 30% following successful stent placement and the absence of major adverse cardiac event (MACE, including cardiac death, myocardial infarction, or target vessel revascularization) up to 7 days post-procedure. The primary endpoint assessed against performance goals derived from major published registries on Shockwave IVL. A subgroup analysis using optical coherence tomography was carried out to evaluate the morphology of calcification before and after IVL treatment, as well as post-stent. RESULTS: From February to April 2023, a total of 184 patients with severely calcified lesions at 11 sites were enrolled. The target lesions were predominantly in the left anterior descending artery (77.2%) and the mean diameter stenosis was 87.6%±6.6%. Procedure success was observed in 96.7% (178/184) of patients (95%CI: 94.2%-99.3%), which significantly surpassed the prespecified performance goal of 85.0% (p < 0.001). All patients met the criteria of angiographic success and 6 (3.3%) patients occurred in-hospital MACE event. The rate of 30-day and 180-day MACE was 3.8% (7/184) and 4.9% (9/184), respectively. In the OCT sub-study population, minimum lumen area increased after IVL by 1.22 ± 0.87 mm² and by an additional 2.54 ± 1.73 mm² post stenting with overall stent expansion of 85.3 ± 17.1% at the site of maximal calcification. No serious adverse events associated with the device were documented. The rates of target lesion failure at 1- and 6-month were 3.3% and 4.4%, respectively. CONCLUSIONS: The novel IVL system could promote stent delivery and achieve optimized stent expansion among patients with severely calcified coronary lesions. TRIAL REGISTRATION: This trial was registered in the clinicaltrials.gov (URL: https://www.clinicaltrials.gov ; Unique identifier: NCT05649488) on 28th November 2022.

Предметные рубрики MeSH