The clinical outcomes of 33 canine eyes following the novel sulcus fixation technique of an injectable acrylic lens through a 3-mm corneal incision.

Ahn Jaesang

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: This retrospective study introduces and evaluates transscleral fixation using a horizontal mattress suture of a conventional injectable acrylic intraocular lens (IOL) inserted through a 3-mm corneal incision in dogs.

MATERIALS AND

METHODS

This technique was applied to four groups: lens subluxation (group SL, n = 15), anterior or posterior lens luxation (group APLL, n = 9), lens capsule tear or rupture (group LCTR, n = 7), and dislocation of the lens capsule containing an IOL (group IOLD, n = 4).

RESULTS

Patients were followed up for an average of 366.7 days (range: 94-830 days) after the surgery. Each IOL was well-centered and the overall visual success rate was 74.3% (26/35). Retinal detachment (4/35) was the most common cause of blindness, followed by glaucoma (3/35), hyphema of unknown etiology (1/35), and severe uveitis accompanied by deep corneal ulcer (1/35).

CONCLUSION

This technique enables sulcus fixation of an IOL, inserted through a 3-mm corneal incision, which is less traumatic than conventional techniques, without the need for specifically designed IOL for sulcus fixation. In this series, this technique enabled to contribute to restore emmetropic vision in dogs.

Для цитирования: Ahn Jaesang. The clinical outcomes of 33 canine eyes following the novel sulcus fixation technique of an injectable acrylic lens through a 3-mm corneal incision.. Veterinary ophthalmology. 2023. DOI: 10.1111/vop.13073.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.