DOI 10.1097/01.mlg.0000180173.81034.4d
Protective effect of isoflurane anesthesia on noise-induced hearing loss in mice.
Аннотация
HYPOTHESIS/
OBJECTIVES
To examine the protective effect of general anesthesia with isoflurane against noise-induced hearing loss in mice.
STUDY
DESIGN
Animal study using noise stimulation and measurement of hearing in BALB/c mice.
METHODS
Mice were exposed to 122 dB peak equivalent sound pressure level click noise for 3 hours per day for 3 consecutive days with or without anesthesia using isoflurane. Hearing levels were measured and hair cell survival ratio was observed.
RESULTS
In mice without anesthesia, hearing threshold increased after noise stimulation (73.7 dB hearing level [HL]) and persisted for at least 1 month. However, in mice exposed to noise under anesthesia, hearing loss was less severe (44.1 dB HL) and had recovered more (26.5 dB HL) by one month. Histological examination showed hair cell survival was higher in anesthetized compared to non-anesthetized mice.
CONCLUSION
These data indicate isoflurane general anesthesia protects against noise-induced hearing loss and tissue damage in mice.