Twenty-seven-gauge vitrectomy: a consecutive, single-centre case series with exclusive use over a 4-year period.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ng Eugene, Masalkhi Mouayad, Steel David H, Pavičić-Astaloš Jasna, Nolan Claire, Mernagh Sarah, Ankamah Emmanuel

Аннотация

BACKGROUND: To assess the safety and effectiveness of the exclusive use of 27-gauge instruments for all vitreoretinal diseases requiring vitrectomy.

METHODS: In this retrospective study, 1020 consecutive surgeries were performed on 958 eyes of 848 patients using 27-gauge instruments from March 2017 to June 2021. Patients with a minimum follow-up of 3 months were included. Surgical case-mix, best-corrected visual acuity (BCVA), intraocular pressure (IOP), intra- and post-operative complications, and surgery times were recorded.

RESULTS: The study patients were followed up for averagely 11 months. Of the 1020 vitrectomies, 958 were primary procedures. Of the 148 retinal detachment (RD) cases, 138 (93%) required a single vitrectomy. Primary macular hole closure was achieved in 143 of 145 (99%) cases. The average surgical times were 55 and 38 min for RD surgeries and for all other indications, respectively. BCVA improved significantly at the final visit (20/49) compared with the pre-operative visit (20/78) (p < 0.01). IOP was similar at the pre-operative (14.8mmHg) and final (14.3mmHg) visits. Complications recorded include transient hypotony in 39 eyes, iatrogenic retinal breaks in 2 eyes, and a vitreous bleed in 1 other eye.

CONCLUSION: This study revealed that 27-gauge vitrectomy instruments can be used for a wide range of indications, with exclusive use in certain settings. The outcomes were similar to other gauges, including for rhegmatogenous retinal detachment, with minimal complications.