MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s383489

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2022

Efficacy and Safety of Temporary in situ Stenting of Ahmed Glaucoma Valve in Eyes with High Risk of Hypotony.

Al Houssien Abdullah Omar, Al Owaifeer Adi Mohammed, Ahmad Sameer I, Owaidhah Ohoud, Malik Rizwan

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION AND

OBJECTIVE

To describe a novel technique for providing external ligation of the Ahmed glaucoma valve (AGV) to prevent hypotony in eyes at high risk with a 4/0 nylon stent suture and report outcomes compared to ligation with an absorbable vicryl suture and no ligation in terms of efficacy and safety.

METHODS

This was a retrospective cohort study investigating the efficacy and safety of in situ stenting compared to an absorbable ligature and the standard care, in high risk eyes, of hypotony. It included 116 patients; 34 in Group A (ligation + stent), 27 in Group B (ligation - stent), and 55 in Group C (no ligation).

RESULTS

The mean age (in years) of the participants was 53.94±19.01 in Group A, 44.85±29.92 in Group B and 52.62±24.47 in Group C, 59% (n = 20), 63% (n = 17) and 60% (n = 33) were males, respectively. The follow-up period was at least 6 months (Group A: 9.1±4.2 months, Group B: 9.6±3.4 months and Group C: 10.2±6.4 months). The mean baseline Snellen VA (LogMAR) was 1.82±1.34, 1.30±0.98 and 1.34±1.07 and the mean baseline IOP was 32.50±9.48, 28.22±7.12 and 28.33±10.63 mmHg, in Groups A, B and C, respectively. The failure rates, by the Kaplan Meier Survival curve, were higher 27.3% in Group C (no ligation) compared to 20.6% in Group A (ligation + stent) and 18.5% in Group B (ligation - stent) yet not found to be statistically significant (p = 0.4; log rank test). There was lower hypotony 2.9% in Group A and lower complications 25.9% in Group B but no statistical significance was found amongst the groups.

CONCLUSION

In conclusion, temporary nylon in situ stenting of AGV had lower rates of hypotony. Furthermore, lower failure and complication rates were observed in vicryl only ligated AGV, then nylon in situ stented AGV and lastly in standard AGV controls.

Для цитирования: Al Houssien Abdullah Omar, Al Owaifeer Adi Mohammed, Ahmad Sameer I, Owaidhah Ohoud, Malik Rizwan. Efficacy and Safety of Temporary in situ Stenting of Ahmed Glaucoma Valve in Eyes with High Risk of Hypotony.. Clinical ophthalmology (Auckland, N.Z.). 2022. DOI: 10.2147/opth.s383489.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.