Retina (Philadelphia, Pa.) · 2022
Four-Point Scleral Fixation of An Akreos Adapt AO Intraocular Lens Using Double-Strand 9-0 Polypropylene Suture.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Chen Shijiu, Yuan Gongqiang, Zhu Wenting, Wang Qian, Shi Weiyun, Zhang Jingjing
Аннотация
PURPOSE: To report the results of a novel surgical four-point transscleral suture fixation of intraocular lens (IOL) with four hollow haptics using the double-suture technique.
METHODS: We retrospectively reviewed the medical records of 15 eyes of 15 patients who underwent 4-point transscleral suture fixation of a foldable IOL using the double-suture technique. Preoperative data and follow-up data for at least 4 months were collected for all patients.
RESULTS: The IOLs were fixed and centered well. The mean preoperative corrected distance visual acuity was 0.70 ± 0.54 logarithm of the minimum angle of resolution (Snellen 20/102), and it improved to 0.29 ± 0.26 logarithm of the minimum angle of resolution (Snellen 20/39) at the final follow-up ( P = 0.001). No vitreous hemorrhage, hypotony, suture breakage, retinal detachment, IOL dislocation, and iris capture was detected during the follow-up period in any of the patients.
CONCLUSION: We have developed a novel technique for 4-point transscleral suture fixation of IOL using the double-suture technique with 9-0 polypropylene suture. This technique seemed to be safe and it may not require the surgeon to learn any new technique.
METHODS: We retrospectively reviewed the medical records of 15 eyes of 15 patients who underwent 4-point transscleral suture fixation of a foldable IOL using the double-suture technique. Preoperative data and follow-up data for at least 4 months were collected for all patients.
RESULTS: The IOLs were fixed and centered well. The mean preoperative corrected distance visual acuity was 0.70 ± 0.54 logarithm of the minimum angle of resolution (Snellen 20/102), and it improved to 0.29 ± 0.26 logarithm of the minimum angle of resolution (Snellen 20/39) at the final follow-up ( P = 0.001). No vitreous hemorrhage, hypotony, suture breakage, retinal detachment, IOL dislocation, and iris capture was detected during the follow-up period in any of the patients.
CONCLUSION: We have developed a novel technique for 4-point transscleral suture fixation of IOL using the double-suture technique with 9-0 polypropylene suture. This technique seemed to be safe and it may not require the surgeon to learn any new technique.