PURPOSE: Early hypotony after non-valved glaucoma drainage device (GDD) implantation for complex glaucomatous eyes with labile aqueous production can lead to significant visual morbidity. We therefore sought to report the early postoperative outcomes of a novel surgical technique that allows atraumatic insertion of non-valved GDDs through a much smaller 25-gauge scleral track, to minimize entry site leakage and improve safety.

METHODS

Retrospective case series of 15 consecutive cases undergoing non-valved GDD insertion into the anterior chamber using a previously unreported technique.

RESULTS

All eyes underwent successful GDD insertion using our novel technique, with no intraoperative complications. The mean preoperative intraocular pressures (IOP), at day 1, week 1 and week 3 were 31.4, 22.4, 23.7, and 25.6 mm Hg, respectively. A statistically significant IOP reduction was achieved at day 1, week 1 and week 3 postoperatively ( P <0.05) without any observed leakage at the scleral entry site. One eye (6.7%) with complex panuveitic glaucoma developed early hypotony (5 mm Hg) with shallow choroidal detachments on day 1. This was successfully managed with 1 intracameral ophthalmic viscoelastic device injection given at the slit-lamp and no further intervention.

CONCLUSIONS

This novel single needle-docking intraocular insertion manoeuvre is an easily adoptable technique to make GDD insertion through a smaller 25-gauge water-tight scleral track more efficient and less traumatic. The technique reduces scleral distortion and therefore improves surgical safety particularly in eyes with complex secondary glaucoma.

Для цитирования: Mohite Abhijit A, Cheng Mei-Ling, Sung Velota C T. A Novel Tube Insertion Technique for Glaucoma Drainage Device Implantation.. Journal of glaucoma. 2022. DOI: 10.1097/ijg.0000000000002080.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.