OBJECTIVE

To determine the therapeutic success and safety of an active transcutaneous bone conduction implant (tBCI) in adult patients with conductive or mixed hearing loss.

STUDY

DESIGN

Retrospective case review.

SETTING

Five university hospitals in Frankfurt, Hannover, Dresden, Würzburg, and Vienna.

PATIENTS: Data were analyzed from 61 patients (31 women, 30 men) with a mean age of 50 years (min. 26, max. 80). Forty patients had mixed, and 21 conductive hearing loss. Typical etiologies were history of otitis media (n = 20) and cholesteatoma (n = 17).

INTERVENTIONS: Implantation of the active tBCI.

MAIN OUTCOME MEASURES: Data were analyzed for the following time points: up to 6 months postoperatively ("short-term"), 6 to 37 months postoperatively ("long-term"), and the last available measurement per patient ("most recent"). Pure-tone audiometry (air and bone conduction, AC and BC) and sound field thresholds with warble tones (WT), word recognition scores with Freiburger monosyllables (WRS), as well as speech reception thresholds (SRT) using the Oldenburg sentence test (OLSA) in quiet (SRT) and in noise (signal-to-noise ratio, SNR) were collected.

RESULTS

No significant changes in air- and bone-conduction thresholds were observed after implantation. A mean WRS improvement of 54% using the active tBCI was shown at the short-term assessment, i.e., a mean score of 79% compared with 25% in the unaided condition. Results remained stable, with a mean score of 75% at the long-term assessment. SRT in noise improved by 3.6 dB SNR in the implanted ear at the short-term assessment. Overall six adverse events and four serious adverse events were reported, resulting in a rate of 9.84 and 6.56%, respectively.

CONCLUSION

The tBCI clearly improves speech intelligibility in patients with conductive or mixed hearing loss, showing stable results up to 1 year post-implantation.

Для цитирования: Rader Tobias, Stöver Timo, Lenarz Thomas, Maier Hannes, Zahnert Thomas, Beleites Thomas, Hagen Rudolf, Mlynski Robert, Baumgartner Wolf Dieter. Retrospective Analysis of Hearing-Impaired Adult Patients Treated With an Active Transcutaneous Bone Conduction Implant.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2018. DOI: 10.1097/mao.0000000000001834.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.