DOI 10.1016/j.ancard.2019.08.002
[Evaluation of the incidence of radiodermatitis lesions in interventional cardiology].
Аннотация
PURPOSE: The percutaneous coronary interventions use large doses of ionizing radiation, particularly when treating complex lesions. The incidence of radio-induced skin lesions is poorly known. Our goal was to evaluate the frequency of occurrence of such lesions, as well as the factors that may contribute to a high radiation dose. The recommended DAP (dose-area product) cutoff for skin monitoring after percutaneous coronary interventions is 500Gy cm2.
PATIENTS AND METHOD: We prospectively studied the incidence of acute (after 5-7 days) and subacute (after 7 days to 6 months) skin lesions following angioplasty with a dose-area product (DAP) ≥200Gy cm2 in patients who underwent coronary angioplasty in our center in 2013.
RESULTS
Nine hundred and thirty three consecutive procedures were analyzed, of which 102 with a DAP ≥200Gy cm2. Three patients presented an acute lesion. Two of these three patients also had subacute lesions. Another patient presented only a subacute lesion. 4.82% (95% CI: [0-10]) of the patients with a DAP ≥200Gy cm2 developed radiodermitis lesions, or 0.47% (95% CI: [0-0.9]) of all the patients who underwent angioplasty. The Body Mass Index and the elective (as opposed to energy) procedures were independently associated with a procedure with a DAP ≥200Gy cm2.
CONCLUSION
Radiodermatitis lesions occur for 4.82% of patients benefiting from procedures with a DAP ≥200Gy cm2. We suggest the establishment of a DAP threshold for dermal monitoring of patients of 200Gy cm2 per procedure instead of 500Gy cm2.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.