Ventricular arrhythmias in Kearns-Sayre syndrome: A cohort study using the National Inpatient Sample database 2016-2019.

Wiseman Kyle, Gor Dhairya, Udongwo Ndausung, Alshami Abbas, Upadhaya Vandan, Daniels Steven J, Chung Wendy K, Koo Charles H

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Degeneration of the cardiac conduction system resulting in complete heart block (CHB), ventricular arrhythmias (VA), and sudden cardiac death (SCD) is recognized in patients with Kearns-Sayre syndrome (KSS) and is potentially preventable with permanent pacemaker (PPM) implantation. However, other mechanisms for SCD have been proposed, and the efficacy of implanting a defibrillator instead of PPM remains to be investigated.

METHODS

We utilized the National Inpatient Sample (NIS) database 2016-2019 to investigate the risk of VA or dysrhythmic cardiac arrest (dCA) in KSS patients. We compared the outcomes of KSS to myotonic dystrophy (MD), a more common genetic disorder with similar clinical cardiac features and course.

RESULTS

We identified 640 admissions for KSS. VA or dCA were lower in admissions for KSS than MD patients (2.3% vs. 4.5%, p = .009). Device implantation differed between study groups. Approximately, 70% of cases with KSS and conduction abnormalities had pacemaker (± defibrillator) on hospital discharge, compared to 35% in MD. Conduction abnormalities were associated with higher rates of VA or dCA in both study groups. None of the admissions for KSS patients who developed VA or dCA had a pacemaker, and all of them had conduction abnormalities. One-third of admissions for MD patients who developed VA or dCA had a device already implanted prior to the event.

CONCLUSION

Despite its effectiveness in preventing VA, PPM remains underutilized in patients with KSS or MD who have conduction abnormalities. PPM alone do not fully prevent VA in MD patients; therefore, addition of defibrillator capacity might be necessary.

Для цитирования: Wiseman Kyle, Gor Dhairya, Udongwo Ndausung, Alshami Abbas, Upadhaya Vandan, Daniels Steven J, Chung Wendy K, Koo Charles H. Ventricular arrhythmias in Kearns-Sayre syndrome: A cohort study using the National Inpatient Sample database 2016-2019.. Pacing and clinical electrophysiology : PACE. 2022. DOI: 10.1111/pace.14607.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.