MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/nu11061383

Медицинская библиотека · Nutrients · 2019

Congruency of Genetic Predisposition to Lactase Persistence and Lactose Breath Test.

Coluccia Enza, Iardino Patrizia, Pappalardo Diego, Brigida Anna Lisa, Formicola Vincenzo, De Felice Bruna, Guerra Claudia, Pucciarelli Alessia, Amato Maria Rosaria, Riegler Gabriele, De Magistris Laura

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

The physiological decline of lactase production in adulthood, in some individuals, is responsible for the so-called "Lactose Intolerance." This clinical syndrome presents with gastrointestinal and non-gastrointestinal symptoms following the consumption of dairy containing food. Lactose intolerance can be evaluated by means of the Lactose Breath Test (phenotype) and/or genetic evaluation of lactase-gene polymorphism (genotype). A comparison of the two tests was carried out in a large number of symptomatic adult subjects, which are selected and not representative of the general population. Congruency was as high as 88.6%. Among lactase non-persistent (genotype C/C), 14 subjects showed a negative Lactose Breath Test (LBT), possibly due to young age. Among lactase-persistent (genotype C/T), four subjects showed a positive LBT, which helps to diagnose secondary lactose intolerance. Symptoms, both gastrointestinal and extra-gastrointestinal, were reported by 90% of patients during the breath test. Clinical use of both tests in the same patients could be taken into consideration as a sharp diagnostic tool. We suggest considering the use of the genetic test after LBT administration, when secondary hypolactasia is suspected, for completion of diagnostic procedures.

Для цитирования: Coluccia Enza, Iardino Patrizia, Pappalardo Diego, Brigida Anna Lisa, Formicola Vincenzo, De Felice Bruna, Guerra Claudia, Pucciarelli Alessia, Amato Maria Rosaria, Riegler Gabriele, De Magistris Laura. Congruency of Genetic Predisposition to Lactase Persistence and Lactose Breath Test.. Nutrients. 2019. DOI: 10.3390/nu11061383.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.