m+Medelevator.RU
← Поиск публикаций
Coronary artery disease · 2026

Comparative effectiveness of Orsiro, Xience, Synergy, and Resolute stent in patients with acute myocardial infarction undergoing percutaneous coronary intervention: a nationwide registry study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Park Hyun Woong, Kim Yong Kyun, Seong Seok-Woo, Lee Jae-Hwan, Kim Mi Joo, Song Pil Sang, Jin Seon-Ah, Ahn Kye Taek, Ahn Youngkeun, Park Sang Hyun, Hwang Jin-Yong, Yoon Chang-Hwan, Jeong Jin-Ok, KAMIR Investigators

Аннотация

BACKGROUND: Head-to-head comparisons of contemporary drug-eluting stents (DES) in patients with acute myocardial infarction (AMI) remain limited. We sought to compare the long-term clinical outcomes of four widely used DES platforms: Orsiro, Xience, Synergy, and Resolute.

METHODS: From the nationwide prospective Korea acute myocardial infarction registry-V, we identified 9284 patients with AMI undergoing percutaneous coronary intervention with one of the four study devices (Orsiro, n = 1634; Xience, n = 2576; Synergy, n = 2811; Resolute, n = 2263). The primary endpoint was target lesion revascularization (TLR). Inverse probability of treatment weighting was performed to adjust for baseline differences.

RESULTS: During a median follow-up of 723 days, the cumulative incidence of TLR differed significantly among groups. In IPTW-adjusted analyses, compared with the Orsiro group (reference), the risk of TLR was significantly higher in the Synergy [hazard ratio: 2.30; 95% confidence interval (CI): 1.20-4.41, P = 0.013] and Resolute groups (hazard ratio: 2.30, 95% CI: 1.18-4.47, P = 0.014). The Xience group showed a comparable risk of TLR to Orsiro (hazard ratio: 1.40, 95% CI: 0.69-2.82, P = 0.346). Target vessel revascularization followed a similar pattern, favoring Orsiro. However, there were no significant differences in composite major adverse cardiovascular events or all-cause mortality among the four groups.

CONCLUSION: In this large-scale, real-world AMI cohort, the ultrathin-strut, biodegradable-polymer Orsiro stent was associated with a lower risk of repeat revascularization compared with the Synergy and Resolute stents. Xience demonstrated comparable outcomes to Orsiro. Stent selection remains a crucial determinant of vessel-level outcomes in patients with AMI.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты