MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8159.1979.tb04275.x

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 1979

Ventricular tachycardia and ventricular fibrillation in patients with short P-R intervals and narrow QRS complexes.

Myerburg R J, Sung R J, Castellanos A

Клинический случайСтатьяПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

Eleven patients with short P-R intervals and narrow QRS complexes had ventricular tachycardia due to organic heart disease: mitral valve prolapse with mitral insufficiency (2 patients); alcoholic (?) cardiomyopathy (2 patients); and coronary artery disease (7 patients). Intracardiac studies showed short A-H intervals during sinus rhythm in all cases. The onset of ventricular fibrillation (which, to our knowledge, has not been observed in patients having short P-R and A-H intervals coexisting with narrow QRS complexes) was documented in 4 cases. Only 1 patient (with quinidine syncope) had been premedicated. In the 3 other patients the episodes of ventricular fibrillation appeared during bouts of atrial fibrillation with rapid ventricular rates which could have been an exprerssion of the "enhanced A-V conduction" that had been manifested in sinus beats by short P-R and A-H intervals. In clinical settings and physiological conditions proven to be hemodynamically unstable (such as transient ischemia or acute myocardial infarction) these rapid ventricular rates could have led to ventricular fibrillation; directly because of the R-on-T phenomenon, and/or indirectly due to decreased coronary perfusion. Ventricular tachycardia and ventricular fibrillation due to organic heart disease probably occur more often than suggested by the few reported cases in the literature. Its significance, however, has to be clarified by further prospective studies.

Для цитирования: Myerburg R J, Sung R J, Castellanos A. Ventricular tachycardia and ventricular fibrillation in patients with short P-R intervals and narrow QRS complexes.. Pacing and clinical electrophysiology : PACE. 1979. DOI: 10.1111/j.1540-8159.1979.tb04275.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.