MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00392-026-02916-4

Медицинская библиотека · Clinical research in cardiology : official journal of the German Cardiac Society · 2026

Hospitalization profiles and complications across ICD and CRT-D implantations in Germany: data from the VIDEO study.

Aktemur Oezalp Tugba, Ukita Kohei, Riemer Thomas, Senges Jochen, Brachmann Johannes, Lewalter Thorsten, Deneke Thomas, Doll Nicolas, Eckardt Lars, Steven Daniel, Akin Ibrahim, Tilz Roland Richard

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Implantable cardioverter-defibrillator (ICD) is a cornerstone therapy for the prevention of sudden cardiac death. However, clinical profiles and in-hospital outcomes may differ according to device type-single-chamber ICD, dual-chamber ICD, or cardiac resynchronization therapy defibrillator (CRT-D). This study aimed to compare hospitalization parameters and peri-procedural complications among patients receiving these device types.

METHODS

We retrospectively analyzed 2,001 consecutive ICD recipients (single-chamber: 815; dual-chamber: 463; CRT-D: 723). Baseline characteristics, intensive care unit (ICU) utilization, procedure-related complications, and discharge outcomes were compared across groups. The main endpoint was defined as major adverse cardiovascular and cerebrovascular events (MACCE), and the second endpoint was defined as an extended MACCE including both MACCE and intensive care unit (ICU) admission.

RESULTS

CRT-D recipients were older (67.5 ± 10.4 years, p < 0.01) and had a higher prevalence of comorbidities, including obesity (12.3%, p = 0.03), diabetes mellitus (30.2%, p = 0.04), permanent atrial fibrillation (10.1%, p < 0.01), and chronic kidney disease (31%, p < 0.01), compared with single- and dual-chamber ICD patients. Post-procedural ICU admission was highest in the dual-chamber ICD group (44.5%, p < 0.01), while ICU stay was shortest among CRT-D recipients (median 2.9 days, p < 0.01), who also required mechanical ventilation less frequently (8.7%, p < 0.01). Overall complication rates were lowest in the single-chamber ICD group (7.5%). Compared with single-chamber ICDs, implantation of dual-chamber ICDs was associated with a significantly higher risk of extended MACCE [OR:1.65, (95% CI:1.30-2.09)], whereas CRT-Ds were associated with a significantly lower risk [OR:0.75, (95% CI:0.60-0.94)]. Furthermore, CRT-Ds were associated with a substantially lower extended MACCE risk compared with dual-chamber ICDs [OR: 0.45, (95% CI:0.35-0x".58)]. Defibrillator type and age emerged as significant predictors of MACCE. For the extended MACCE endpoint, defibrillator type remained a significant predictor, whereas age was not.

CONCLUSION

Despite their older age and higher comorbidity burden, recipients of CRT-D exhibited the lowest incidence of MACCE. Defibrillator type and age were identified as relevant predictors of MACCE in this patient population.

Для цитирования: Aktemur Oezalp Tugba, Ukita Kohei, Riemer Thomas, Senges Jochen, Brachmann Johannes, Lewalter Thorsten, Deneke Thomas, Doll Nicolas, Eckardt Lars, Steven Daniel, Akin Ibrahim, Tilz Roland Richard. Hospitalization profiles and complications across ICD and CRT-D implantations in Germany: data from the VIDEO study.. Clinical research in cardiology : official journal of the German Cardiac Society. 2026. DOI: 10.1007/s00392-026-02916-4.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.