Gap-induced inhibition of the post-auricular muscle response in miniature pigs.

Zhou Hanwen, Liu Peng, Zhang Chi, Xue Xinmiao, Chen Xuemin, Zhang Zhixin, Shen Weidong, Yang Shiming, Fan Mengyun, Wang Fangyuan

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Tinnitus, a persistent condition that significantly impairs the quality of life for patients, poses a substantial burden on society. Owing to its complex and poorly understood pathogenesis, the development of effective animal models for tinnitus is imperative to enhance our comprehension of this condition.

OBJECTIVES

The present study aims to establish a large animal model to delineate the mechanisms underlying the onset of tinnitus.

MATERIALS AND

METHODS

For the first time, we conducted a comparative analysis of the Post-Auricular Muscle Response (PAMR) and the Eye Blink Response (EBR) in miniature pigs, demonstrating their utility in manifesting Gap Prepulse Inhibition of the Acoustic Startle (GPIAS). Subsequently, we employed the gap-induced inhibition of PAMR to ascertain evidence of tinnitus following noise exposure.

RESULTS AND

CONCLUSION

Through comparing the efficacy of PAMR and EBR in GPIAS detection, we have substantiated that PAMR provides a stable and objective reflection of GPIAS. Consequently, PAMR emerges as a reliable method for measuring GPIAS in miniature pigs. Furthermore, the behavioral paradigm of gap-induced inhibition of PAMR successfully identified behavioral evidence of tinnitus subsequent to noise exposure.

Для цитирования: Zhou Hanwen, Liu Peng, Zhang Chi, Xue Xinmiao, Chen Xuemin, Zhang Zhixin, Shen Weidong, Yang Shiming, Fan Mengyun, Wang Fangyuan. Gap-induced inhibition of the post-auricular muscle response in miniature pigs.. Acta oto-laryngologica. 2025. DOI: 10.1080/00016489.2025.2464698.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.