m+Medelevator.RU
← Поиск публикаций
European heart journal. Digital health · 2026

Artificial intelligence-enabled electrocardiography for detection of left ventricular diastolic dysfunction: a systematic review and meta-analysis.

СтатьяОбзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Edjimbi Johann, Shah Nisarg, Donisi Luca, Gajjar Aryan, See Claudia, Grimshaw Alyssa A, Diop Hassim Bachir, Ribeiro Antonio Luiz P, Marijon Eloi, Clifford Gari, Gaye Bamba

Аннотация

Left ventricular diastolic dysfunction (LVDD) is an early precursor to heart failure with preserved ejection fraction, and it is currently diagnosed using echocardiography, a resource-intensive and operator-dependent modality that limits large-scale screening. The 12-lead electrocardiogram (ECG) is widely available but lacks sufficient diagnostic accuracy for LVDD. Artificial intelligence (AI)-enhanced ECG analysis has emerged as a potential scalable alternative, although its overall diagnostic performance remains uncertain. This study aims to evaluate the diagnostic accuracy of AI-based algorithms for detecting LVDD in a systematic review and meta-analysis. We systematically searched eight major databases through August 2025, complemented by forward and backward citation chasing. Studies reporting sensitivity and specificity of AI-ECG models, using echocardiography as the reference standard, were included. Pooled sensitivity, specificity, and area under the summary receiver operating characteristic curve (AUC) were estimated using a bivariate random-effects model. Five studies including 105 554 participants were analysed. AI-ECG demonstrated a pooled sensitivity of 0.82 (95% CI: 0.81-0.83) and specificity of 0.77 (95% CI: 0.70-0.82), with an AUC of 0.85 (95% CI: 0.81-0.87). Substantial heterogeneity was observed (I 2 = 98.5% for sensitivity and 99.8% for specificity), although results were robust in sensitivity analyses. Predictive values were prevalence-dependent. Negative predictive value was 98.8% at 5% prevalence and 93.7% at 22.2%, but declined to 81.1% at 50% prevalence and 64.7% at 70%. Artificial intelligence-enhanced electrocardiography demonstrated good diagnostic performance for detecting LVDD and may support future rule-out or risk-enrichment strategies in selected populations. However, current evidence remains insufficient to support routine clinical implementation.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты