m+Medelevator.RU
← Поиск публикаций
European heart journal. Imaging methods and practice · 2026

Fully automated deep learning MAPSE: retrospective analysis and real-time clinical application.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Haga Maria Muan, Katla Nora Lindeman, Holmstrøm Vegard, Holte Espen, Stølen Stian, Stensæth Knut Haakon, Østvik Andreas, Løvstakken Lasse, Dalen Håvard, Smistad Erik, Grenne Bjørnar

Аннотация

AIMS: Mitral annular plane systolic excursion (MAPSE) is an accessible echocardiographic measure of left ventricular (LV) function. However, manual measurement methods are operator-dependent and time-consuming. We developed a multistep deep learning (DL) method for off-line and real-time fully automated MAPSE estimation, and aimed to assess agreement, reproducibility, time efficiency, and feasibility compared with standard manual measurements.

METHODS AND RESULTS: The DL-based method was evaluated in two retrospective cohorts (n = 1775) and one prospective cohort (n = 51). Agreement between DL-MAPSE on B-mode images and experts' manual M-mode measurements was evaluated in all datasets. Evaluation of test-retest reproducibility, time efficiency using real-time analysis during acquisition, and agreement with cardiac magnetic resonance (CMR)-imaging were performed in subsets of the datasets. DL-MAPSE demonstrated good agreement with manual measurements, with bias 2.9 mm (95% CI 2.8-3.0 mm) and Pearson coefficient 0.81 (95% CI 0.79-0.84) in the primary dataset, and a lower bias of 1.0 mm against CMR-MAPSE compared with -2.1 mm using manual M-mode. Both DL and manual measurements showed good test-retest reproducibility (ICC 0.82 and 0.76, respectively). Real-time DL measurements reduced measurement and acquisition time by 51% (mean 1 min 50 s) per examination. The DL method demonstrated excellent feasibility (96%).

CONCLUSION: This novel DL method for fully automated MAPSE demonstrated excellent feasibility, robust reproducibility, and good agreement with both manual M-mode and CMR-derived measurements. Automated DL-MAPSE could substantially reduce analysis time and enhance reproducibility, increasing its clinical value as a marker of LV systolic function.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты